Evidence map›Paper›PMID 42684918›Full record

ArticleMicrobiology spectrum2026

Dual readout RT-LAMP for rapid on-site dengue virus detection and serotyping.

Rebecca Brambilla, Neesha Rockwood, Janine Michel, Kalpa Kariyawasam, Hansi Ganhewa, Johannes Scholz, Inoka C Perera, Andreas Nitsche, Andreas Puyskens

Abstract read
In one paragraph

Article in Microbiology spectrum, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Rebecca BrambillaRobert Koch Institute, Centre for Biological Threats and Special Pathogens, ZBS 1: Highly Pathogenic Viruses, WHO Reference Laboratory for SARS-CoV-2 and WHO Collaborating Centre for Emerging Infections and Biological Threats, Berlin, Germany.
Neesha RockwoodDepartment of Medical Microbiology and Immunology, Faculty of Medicine, University of Colombo, Colombo, Sri Lanka.
Janine MichelRobert Koch Institute, Centre for Biological Threats and Special Pathogens, ZBS 1: Highly Pathogenic Viruses, WHO Reference Laboratory for SARS-CoV-2 and WHO Collaborating Centre for Emerging Infections and Biological Threats, Berlin, Germany.ORCID 0000-0001-6227-3125
Kalpa KariyawasamDepartment of Medical Microbiology and Immunology, Faculty of Medicine, University of Colombo, Colombo, Sri Lanka.
Hansi GanhewaDepartment of Zoology and Environment Sciences, University of Colombo, Colombo, Sri Lanka.
Johannes ScholzRobert Koch Institute, Centre for Biological Threats and Special Pathogens, ZBS 1: Highly Pathogenic Viruses, WHO Reference Laboratory for SARS-CoV-2 and WHO Collaborating Centre for Emerging Infections and Biological Threats, Berlin, Germany.
Inoka C PereraDepartment of Zoology and Environment Sciences, University of Colombo, Colombo, Sri Lanka.ORCID 0000-0002-2496-7385
Andreas NitscheRobert Koch Institute, Centre for Biological Threats and Special Pathogens, ZBS 1: Highly Pathogenic Viruses, WHO Reference Laboratory for SARS-CoV-2 and WHO Collaborating Centre for Emerging Infections and Biological Threats, Berlin, Germany.ORCID 0000-0001-8185-3176
Andreas PuyskensRobert Koch Institute, Centre for Biological Threats and Special Pathogens, ZBS 1: Highly Pathogenic Viruses, WHO Reference Laboratory for SARS-CoV-2 and WHO Collaborating Centre for Emerging Infections and Biological Threats, Berlin, Germany.ORCID 0000-0002-6492-9463

Funding

Bundesministerium für Gesundheit 1503-68404
6 · The paper itself

Abstract

Dengue is the fastest-growing mosquito-borne disease, with over 14 million reported cases globally in 2024, rendering dengue a major public health issue of global concern. Fast and reliable serotype-specific diagnosis of dengue is critical for patient risk management and epidemiological surveillance. While real-time PCR currently remains the gold standard for dengue virus detection, it requires thermal cyclers and trained personnel in an established laboratory infrastructure, limiting its use in low-resource settings. Loop-mediated isothermal amplification (LAMP) offers a promising alternative, yet currently available reverse transcription assays for dengue either rely on limited sequences used for primer design, thus failing to adequately capture global genetic diversity, or use multiple primer sets, increasing complexity and costs. We developed four serotype-specific dengue virus (DENV) reverse transcription (RT)-LAMP assays in which primer design was informed by 4,277 whole-genome sequences from different geographical regions. Degenerate base positions were incorporated into primers to achieve broad detection capability while minimizing the number of distinct oligonucleotides needed. The assays achieved analytical sensitivities of 96-734 genome equivalents per reaction after 60 min. Clinical evaluation using 95 PCR-confirmed positive samples from Sri Lanka, including serotypes 1-3, demonstrated detection rates of 91.2% for DENV1, 78.6% for DENV2, and 100% for DENV3, with no cross-reactivity observed between serotypes. Evaluation using DENV4-spiked serum demonstrated reliable detection at clinically relevant viral loads, with complete detection at quantification cycle (Cq) values of ~30. A dual readout design enables both real-time fluorescence detection and equipment-free visual colorimetric detection, rendering the assays suitable for point-of-care applications in dengue-endemic regions worldwide. IMPORTANCE: Dengue virus infections pose a growing threat to global health, with cases doubling annually since 2021, yet reliable diagnostic tools remain inaccessible in many affected regions. Current gold-standard molecular tests require expensive equipment and specialized laboratories, creating a critical gap in dengue-endemic areas where rapid, on-site diagnosis could save lives through early patient management and outbreak control. This study addresses this gap by developing dengue virus serotype-specific detection assays that work at a constant temperature without the need for sophisticated and expensive equipment. By analyzing thousands of dengue virus genome sequences and strategically incorporating degenerate bases, we designed primers that can detect diverse viral strains while maintaining simplicity and low cost. The assays provide results in 40-60 min, depending on the workflow, and can be read visually without instruments, making them practical for use in clinics, field settings, and resource-limited laboratories where dengue burden is highest.

Indexed as

DengueDengue VirusMolecular Diagnostic TechniquesNucleic Acid Amplification TechniquesSerotypingDNA PrimersHumansRapid Diagnostic TestsRNA, ViralSensitivity and SpecificitySerogroupDNA PrimersRNA, Viraldengue serotypingisothermal amplificationloop-mediated isothermal amplificationmolecular diagnosticspoint-of-care diagnosticsvisual detection

Identifiers

PMID42684918
PMCPMC13689443

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.