Evidence map›Paper›PMID 42683230›Full record

ArticleSensors and actuators. A, Physical2025

Optical crosstalk between SiPMs in dual-ended readout.

Nicolaus Kratochwil, Emilie Roncali, Joshua W Cates, Gerard Ariño-Estrada

Abstract read
In one paragraph

Article in Sensors and actuators. A, Physical, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Nicolaus KratochwilDepartment of Biomedical Engineering, University of California, Davis, Davis, 95616, CA, United States of America.ORCID 0000-0001-5297-1878
Emilie RoncaliDepartment of Biomedical Engineering, University of California, Davis, Davis, 95616, CA, United States of America.ORCID 0000-0002-2439-1064
Joshua W CatesLawrence Berkeley National Laboratory, Berkeley, 94720, CA, United States of America.ORCID 0000-0002-5649-8691
Gerard Ariño-EstradaDepartment of Biomedical Engineering, University of California, Davis, Davis, 95616, CA, United States of America.ORCID 0000-0002-6411-191X

Funding

TOF-PET with high-efficiency TlCl crystalsR01EB034062 · NIBIB · UNIVERSITY OF CALIFORNIA AT DAVIS · PI Gerard Arino Estrada · 2023 to 2026
$2.5M
Low cost and high performance time-of-flight PET detectorsR01EB028286 · NIBIB · UNIVERSITY OF CALIF-LAWRENC BERKELEY LAB · PI CATES, JOSHUA WILLIAM · 2020 to 2023
$1.9M
NIBIB NIH HHS R01 EB028286NIBIB NIH HHS R01 EB034062
6 · The paper itself

Abstract

Gamma-ray detection performance in scintillation crystals can be improved by coupling multiple photodetectors around the sensitive volume. Greater light collection leads to improved time and energy resolution. However, neighboring detector noise, both uncorrelated and correlated, can produce optical photons that may deteriorate their performance. We studied the impact of external optical crosstalk in a dual-ended readout setup using AFBR-S4N44P014M silicon photomultipliers (SiPMs) from Broadcom coupled to 20 mm thick bismuth germanate (BGO) crystal, with and without scintillation light. SiPMs were biased individually. The behavior of crosstalk was analytically modeled. The dark count rate increased up to 50 % when both SiPMs were biased with respect to only one active SiPM. At the same time, the crosstalk probability increased more than 2-fold at high overvoltages due to detection and re-emission of avalanche photons, limiting the operational range and causing an up to 5-fold increase in the total number of detected photons. Energy resolution in BGO was impacted, and the coincidence time resolution distribution shape between two BGO detectors was significantly altered- both in a non-intuitively manner. Experimental results validate the analytical model which rely on a single constant to predict dark count rate, crosstalk and light output enhancement. Crosstalk in multi-SiPM configurations, especially at high overvoltage, significantly impacts performance. Deep understanding of the effects of excess noise in SiPM is crucial for an optimal overall gamma detector operation. Findings extend to applications in high-energy physics, time-of-flight positron emission tomography using dual-ended or monolithic crystals, and cryogenic SiPM experiments in neutrino/dark matter studies.

Indexed as

Bismuth germanium oxide (BGO)CalorimetryCrosstalkDark count rate (DCR)Excess noiseFast timingSilicon photomultiplier (SiPM)Single photon time resolution (SPTR)TOF-PET

Identifiers

PMID42683230
PMCPMC13533413

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.