ArticleSensors and actuators. A, Physical2025
Optical crosstalk between SiPMs in dual-ended readout.
Article in Sensors and actuators. A, Physical, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
Abstract
Gamma-ray detection performance in scintillation crystals can be improved by coupling multiple photodetectors around the sensitive volume. Greater light collection leads to improved time and energy resolution. However, neighboring detector noise, both uncorrelated and correlated, can produce optical photons that may deteriorate their performance. We studied the impact of external optical crosstalk in a dual-ended readout setup using AFBR-S4N44P014M silicon photomultipliers (SiPMs) from Broadcom coupled to 20 mm thick bismuth germanate (BGO) crystal, with and without scintillation light. SiPMs were biased individually. The behavior of crosstalk was analytically modeled. The dark count rate increased up to 50 % when both SiPMs were biased with respect to only one active SiPM. At the same time, the crosstalk probability increased more than 2-fold at high overvoltages due to detection and re-emission of avalanche photons, limiting the operational range and causing an up to 5-fold increase in the total number of detected photons. Energy resolution in BGO was impacted, and the coincidence time resolution distribution shape between two BGO detectors was significantly altered- both in a non-intuitively manner. Experimental results validate the analytical model which rely on a single constant to predict dark count rate, crosstalk and light output enhancement. Crosstalk in multi-SiPM configurations, especially at high overvoltage, significantly impacts performance. Deep understanding of the effects of excess noise in SiPM is crucial for an optimal overall gamma detector operation. Findings extend to applications in high-energy physics, time-of-flight positron emission tomography using dual-ended or monolithic crystals, and cryogenic SiPM experiments in neutrino/dark matter studies.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.