Evidence map›Paper›PMID 42683097›Full record

ArticleRadiology research and practice2026

Biomechanical Assessment Using MRI of Custom-Made Bovine Pericardial Tubes as Potential Aortic Replacements.

Abdulrahman Alblowi, Pierre-André Vuissoz, Siyu Lin, Olivier Bouchot, Thomas Decourselle, Jacques Felblinger, Nicla Settembre, Alain Lalande, Serguei Malikov

Abstract read
In one paragraph

Article in Radiology research and practice, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Abdulrahman AlblowiDepartment of Vascular and Endovascular Surgery, Nancy Regional University Hospital, University of Lorraine, INSERM UMRS 1116 DCAC, Nancy, France, univ-lorraine.fr.ORCID https://orcid.org/0000-0003-0921-7030
Pierre-André VuissozIADI U1254, INSERM and Université de Lorraine, Nancy, France.ORCID https://orcid.org/0000-0003-3519-1743
Siyu LinICMUB CNRS UMR 6302, Université Bourgogne Europe, Dijon 21000, France.
Olivier BouchotICMUB CNRS UMR 6302, Université Bourgogne Europe, Dijon 21000, France.
Thomas DecourselleCASIS-Cardiac Simulation & Imaging Software SAS, Quetigny, France.
Jacques FelblingerIADI U1254, INSERM and Université de Lorraine, Nancy, France.ORCID https://orcid.org/0000-0002-9245-6595
Nicla SettembreDepartment of Vascular and Endovascular Surgery, Nancy Regional University Hospital, University of Lorraine, INSERM UMRS 1116 DCAC, Nancy, France, univ-lorraine.fr.
Alain LalandeICMUB CNRS UMR 6302, Université Bourgogne Europe, Dijon 21000, France.ORCID https://orcid.org/0000-0002-7970-366X
Serguei MalikovDepartment of Vascular and Endovascular Surgery, Nancy Regional University Hospital, University of Lorraine, INSERM UMRS 1116 DCAC, Nancy, France, univ-lorraine.fr.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction: Autologous materials for vessel replacement in infected fields have high morbidity and mortality rates. Custom-made bovine pericardial tubes (CMBPTs) offer a promising alternative with advantages such as reliability, strength, and availability. However, limited biomechanical data hinder predictions of in vivo performance. This study evaluates the physiological strain and distensibility of CMBPTs in vitro under simulated abdominal aortic flow using magnetic resonance imaging (MRI). A secondary objective is to compare strain and distensibility calculations using phase contrast (PC) and steady-state free precession (SSFP) MRI sequences. Methods: Seven CMBPTs were tested under physiological aortic conditions with a pulsatile flow rate of 1650 mL/min using in vitro MRI. PC and SSFP sequences were employed, with PC estimating velocity and strain, while SSFP assessed strain separately. Image analysis was performed using QIR-MR software. Results: Strain was measured using magnitude images. The mean maximum cross-sectional areas were 419 ± 22.1 (PC) and 438.4 ± 24.3 mm Conclusion: CMBPTs exhibit biomechanical properties similar to the abdominal aorta, suggesting potential for vascular applications. Both MRI sequences provided comparable results, supporting their reliability. Further research is needed to confirm long-term performance.

Indexed as

custom-made bovine pericardial tubedistensibilityMRIstrain percentagevelocityxenograft material

Identifiers

PMID42683097
PMCPMC13531373

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.