Measurement error in bioimpedance spectroscopy: The role of electrode type and analyzer.

Carina M Velasquez, Ainsley E Way, Christian Rodriguez, Ethan G Tinoco, Christine M Florez, Madelin R Siedler, Todd J Freeborn, Grant M Tinsley

Abstract read
In one paragraph

Article in Journal of electrical bioimpedance, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Carina M VelasquezEnergy Balance & Body Composition Laboratory, Dept. of Kinesiology and Sport Management, Texas Tech University, Lubbock, TX, USA.
Ainsley E WayEnergy Balance & Body Composition Laboratory, Dept. of Kinesiology and Sport Management, Texas Tech University, Lubbock, TX, USA.
Christian RodriguezEnergy Balance & Body Composition Laboratory, Dept. of Kinesiology and Sport Management, Texas Tech University, Lubbock, TX, USA.
Ethan G TinocoEnergy Balance & Body Composition Laboratory, Dept. of Kinesiology and Sport Management, Texas Tech University, Lubbock, TX, USA.
Christine M FlorezEnergy Balance & Body Composition Laboratory, Dept. of Kinesiology and Sport Management, Texas Tech University, Lubbock, TX, USA.
Madelin R SiedlerDepartment of Exercise and Health Science, College of Saint Benedict and Saint John's University, Saint Joseph, MN, USA.
Todd J FreebornDepartment of Electrical and Computer Engineering, The University of Alabama, Tuscaloosa, AL, USA.
Grant M TinsleyEnergy Balance & Body Composition Laboratory, Dept. of Kinesiology and Sport Management, Texas Tech University, Lubbock, TX, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Bioimpedance spectroscopy (BIS) is a non-invasive method used to assess body composition in a variety of settings. Although BIS has been reported as an accurate measure of body composition, the magnitude of within-day technical error associated with different BIS devices and electrode types remains unknown. Therefore, the purpose of this study was to assess the technical error of measurement (TEM) between single-tab and double-tab electrodes across two BIS devices for resistance, reactance, phase angle, total body water, fat-free mass, and fat mass. One hundred and four adults reported to the laboratory for a single visit, undergoing twelve different assessments utilizing single- and double-tab electrodes on two BIS analyzers of the same model. The within-day technical error was assessed as the absolute and relative TEM for each of the variables. The results indicated that intra-analyzer assessments displayed the lowest amount of error for all the variables (relative TEM = 0.05 - 0.28%) while the largest TEMs were observed for comparisons between single-tab and double-tab assessments (relative TEM = 1.04 - 3.68%), except for reactance. For reactance alone, the TEMs were greatest for the inter-analyzer comparison with double-tab electrodes (absolute TEM = 1.07 Ω; relative TEM = 1.68%). While all assessments displayed relatively low technical error, the present results reinforce the importance of consistently using the same analyzer and electrode type to minimize errors when assessing body composition using BIS, particularly when seeking to identify subtle changes in BIS output.

Indexed as

Bioimpedancebody compositionelectrical impedanceelectrodes