Size-specific weighted detectability index for computed tomography image characterization.

Isabelle Fitton, Joël Greffier, Djamel Dabli, Claire Van Ngoc Ty

Abstract read
In one paragraph

Article in Medical physics, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Isabelle FittonDepartment of Radiology, Université de Paris; Assistance Publique Hôpitaux de Paris, Hôpital Européen Georges Pompidou, Paris, France.
Joël GreffierDepartment of Medical Imaging, IMAGINE UR UM 103, Montpellier University, Nîmes University Hospital, Nîmes, France.
Djamel DabliDepartment of Medical Imaging, IMAGINE UR UM 103, Montpellier University, Nîmes University Hospital, Nîmes, France.
Claire Van Ngoc TyDepartment of Radiology, Université de Paris; Assistance Publique Hôpitaux de Paris, Hôpital Européen Georges Pompidou, Paris, France.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundTechnological developments in computed tomography (CT) have increased the diversity of acquisition and reconstruction strategies available for clinical imaging. Task-based image quality metrics that account for patient-size variability are needed to characterize reconstructed image performance and support protocol optimization across clinically relevant imaging conditions. PURPOSE: To propose and evaluate a novel size-specific weighted detectability index (SSW-d'), a task-based image performance metric (d') that incorporates lesion contrast weighting and water-equivalent diameter variability for the characterization of CT images acquired at low dose.

methodsFirst, a multi-sized image quality phantom was scanned on two CT systems: one photon-counting CT (PCCT, CT1) and one CT equipped with energy integrating detectors (EICT, CT2). Acquisitions were performed with a volume CT dose index (CTDI

resultsOn CT1, the highest SSW-d' values were 19.3 ± 0.3 and 6.9 ± 0.0, at 120 kV for bone and iodine rods, respectively. On CT2, the highest SSW-d' results were 19.0 ± 0.3 and 4.9 ± 0.0 at Sn100 kV for bone and iodine rods, respectively. The lowest values were at Sn140kV for both rods and CT systems. When encompassing both tasks, the maximum SSW-d' values were 10.05 ± 0.04 and 8.25 ± 0.03, respectively obtained at 120 kV for CT1 and at Sn100 kV for CT2. The results showed that the lowest SSW-d' values were at Sn140 kV for both CT systems. Comparison of acquisition and reconstruction parameters showed that the highest SSW-d' value was obtained using the Br32 kernel (17.6 ± 0.7), approximately twofold higher than that obtained at 6 mGy (8.6 ± 0.3). The lowest SSW-d' value (1.9 ± 0.1) was obtained with FBP, while the highest performance was achieved with QIR-4 reconstruction.

conclusionsA novel metric based on a size-specific weighted detectability index (SSW-d') was developed and evaluated for the characterization of reconstructed CT image performance across a range of patient-equivalent diameters and clinically relevant detection tasks. The proposed SSW-d' consolidates multiple detectability index measurements into a single descriptor that accounts for lesion contrast weighting and patient-size variability. The metric was sensitive to acquisition and reconstruction parameters and proved useful for identifying imaging conditions that maximize task-based performance in ultra-low-dose CT. These findings suggest that SSW-d' may serve as a practical tool for image-quality characterization and protocol optimization across clinically relevant imaging scenarios.

Indexed as

Image Processing, Computer-AssistedTomography, X-Ray ComputedAlgorithmsHumansPhantoms, ImagingRadiation Dosagecomputed tomographydetectability indexsize‐specific weighted detectabilitytask‐based detectionultra‐low dosewater equivalent diameter

Identifiers

PMID42682207
PMCPMC13535753

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.