Evidence map›Paper›PMID 42682194›Full record

ArticleMedical physics2026

Multi-angle fluoroscopic lung perfusion imaging using x-ray pulsatility index: A pilot study in healthy subjects.

Matthew R Smith, Bradley W Richmond, Savannah Gregory, Maggie Cartwright, Andreas Fouras, Greg T Mogel, Charles R Hatt, Gary T Smith, Jared V Grice

Abstract read
In one paragraph

Article in Medical physics, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Matthew R SmithDepartment of Radiology, University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin, USA.
Bradley W RichmondDepartment of Veterans Affairs Medical Center, Nashville, Tennessee, USA.
Savannah GregoryDepartment of Medicine, Division of Allergy, Pulmonary, and Critical Care Medicine, Vanderbilt Health, Nashville, Tennessee, USA.
Maggie CartwrightVanderbilt University Institute of Imaging Science, Nashville, Tennessee, USA.
Andreas Fouras4D Medical, Melbourne, Australia.
Greg T Mogel4D Medical, Melbourne, Australia.
Charles R Hatt4D Medical, Melbourne, Australia.
Gary T SmithDepartment of Radiology, Vanderbilt Health, Nashville, Tennessee, USA.
Jared V GriceDepartment of Radiology, Vanderbilt Health, Nashville, Tennessee, USA.

Funding

CSRD VA I50 CX002551U.S. Department of Veterans Affairs I50CX002551
6 · The paper itself

Abstract

backgroundX-ray pulsatility index (XPI) quantifies cardiac-synchronous attenuation changes as a surrogate for regional lung perfusion, but current implementations are limited by projectional overlap and the lack of reference values in healthy individuals. PURPOSE: To characterize regional XPI patterns and establish preliminary reference values in healthy participants using a novel multi-angle fluoroscopic imaging system.

methodsNineteen healthy participants underwent an 8 s breath-hold during fluoroscopic imaging using 15 fps at four simultaneous projections (LPO, AP caudal, RPO, AP cranial) using a novel scanner. Frames were cropped to exclude initial x-ray tube stabilization and bulk motion. Spectral analysis exploited the periodic signal attenuation in the lungs to create XPI maps, as previously described. To focus on the clinically important regions of lung perfusion, the peripheral 3 cm of lung was manually segmented and divided into upper, middle, and lower lung zones. XPI values from these regions were compared to evaluate laterality and cranial-caudal differences using paired t-tests corrected with the Benjamini-Hochberg procedure to control the False Discovery Rate (FDR). Peripheral XPI contrast-to-noise (pCNR) was calculated in the AP caudal projection to quantify signal-to-background separation. Data were retrospectively resampled to assess the effect of reduced frame rate (7.5, 5 fps) and shorter acquisition time using multiple regression analysis. Radiation dose was estimated using phantom measurements and simulation.

resultsAll participants performed the breath-hold without difficulty. XPI maps demonstrated bilateral lung perfusion across all four views, enabling multi-projection assessment of regional perfusion. No focal defects were observed; however, one participant demonstrated globally reduced XPI. Significant cranial-caudal gradients in XPI were observed across projection angles, consistent with known gravity-dependent physiology. Following FDR adjustment (Q = 0.05), the lower zones continued to demonstrate significantly higher values than the upper zones in 3 of 4 projections (all q < 0.05). There were no significant laterality differences (q > 0.05). XPI values remained stable across acquisition lengths and frame rates, indicating robustness of the metric. CNR increased with longer acquisitions and higher frame rates, reflecting reduced noise and improved signal reliability.

conclusionMulti-angle XPI fluoroscopy enables non-invasive regional lung perfusion assessment with low radiation exposure and provides preliminary reference values for future clinical investigation.

Indexed as

Healthy VolunteersLungPerfusion ImagingAdultFemaleFluoroscopyHumansImage Processing, Computer-AssistedMaleMiddle AgedPilot ProjectsReference ValuesSignal-To-Noise RatioX-RaysYoung Adultlung perfusionspectral analysisx‐ray pulsatility index

Identifiers

PMID42682194
PMCPMC13535757

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.