Evidence map›Paper›PMID 42678613›Full record

ArticleChild's nervous system : ChNS : official journal of the International Society for Pediatric Neurosurgery2026

Real-time visualization of endoscope-brain interactions using a transparent ventricular model.

Kenichi Nishiyama, Tomoru Miwa, Yuto Shirakawa, Hideaki Ono

Abstract read
PubMed Publisher
In one paragraph

Article in Child's nervous system : ChNS : official journal of the International Society for Pediatric Neurosurgery, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Kenichi NishiyamaDepartment of Neurosurgery, Hamagumi Children's Medical and Developmental Support Center of Niigata, Chuou-Ku Suidouchou 1-5932, Niigata, 9518121, Japan. nikken726@gmail.com.
Tomoru MiwaDepartment of Pediatric Neurosurgery, Jichi Children's Medical Center Tochigi, Jichi Medical University, Tochigi, Japan.
Yuto ShirakawaJapan Medical Company Inc.,, Tokyo, Japan.
Hideaki OnoJapan Medical Company Inc.,, Tokyo, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeSafe intraventricular neuroendoscopy requires refined instrument control within narrow and often distorted working corridors. A significant proportion of surgical complications-such as forniceal injury and vascular compromise-arises from mechanical interactions between the endoscope shaft/sheath and intraventricular structures that remain invisible to the surgeon during the procedure. No existing high-fidelity simulator allows for the real-time, external visualization of these "blind" movements. We developed a novel, high-clarity transparent ventricular model to clarify these interactions and provide a robust platform for surgical training and preclinical device validation.

methodsA transparent ventricular model was fabricated using high-clarity urethane and elastomer materials, engineered to approximate the viscoelastic properties and Young's modulus of human cerebral white matter. Critical anatomical landmarks, including the fornix, septal and thalamostriate veins, venous angle, choroid plexus, and mammillary bodies, were delineated using embedded, color-coded PVC films. The model was housed in a water-filled acrylic chamber to match refractive indices and ensure optical clarity. We simulated standard neuroendoscopic procedures-including endoscopic third ventriculostomy (ETV), septostomy, choroid plexus coagulation (CPC), and tumor biopsy-using both rigid and flexible endoscopes via frontal and parietal trajectories. Instrument-tissue interactions were recorded simultaneously via endoscopic and multiple external camera angles.

resultsThe model successfully facilitated the continuous, real-time visualization of structural displacements that are inherently invisible in vivo. During ETV simulation, advancement through the foramen of Monro revealed significant compression and lateral displacement of the forniceal columns, even when the endoscopic view suggested a centralized trajectory. Rigid endoscopes demonstrated a larger "mechanical footprint," transmitting higher shear forces to the parenchyma during sweeping maneuvers. Conversely, flexible scopes allowed for more delicate navigation in the temporal and occipital horns, though tip flexion was observed to cause localized displacement of the interthalamic adhesion. Specific "blind" risks, such as the stretching of the thalamostriate veins during sheath withdrawal, were clearly identified.

conclusionThis transparent model reveals complex mechanical interactions that are crucial for surgical safety but obscured during conventional surgery. By providing a feedback loop for "off-camera" instrument movements, the system serves as an invaluable tool for neurosurgical education, trajectory refinement, and the preclinical evaluation of the next-generation endoscopic instruments.

Indexed as

Cerebral VentriclesModels, AnatomicNeuroendoscopyHumansVentriculostomyForniceal injuryNeuroendoscopyPediatric neurosurgerySurgical simulationTransparentVentricular model

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.