Evidence map›Paper›PMID 42675825›Full record

ArticleMedical science monitor : international medical journal of experimental and clinical research2026

Development and Clinical Feasibility of a Computer-Assisted Shape Design and Bending System for Spinal Fixation Rods.

Xingye Li, Weijun Zhang, Zhongning Xu, Yongqiang Zhao, Yan An, Qingyun Li, Da He

Abstract read
In one paragraph

Article in Medical science monitor : international medical journal of experimental and clinical research, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Xingye LiDepartment of Spine Surgery, Beijing Jishuitan Hospital, Capital Medical University, Beijing, China.
Weijun ZhangSchool of Medical Science and Engineering, Beijing Institute of Technology, Beijing, China.ORCID 0009-0000-0688-4036
Zhongning XuDepartment of Spine Surgery, Beijing Jishuitan Hospital, Capital Medical University, Beijing, China.
Yongqiang ZhaoTINAVI Medical Technologies Co., Ltd., Beijing, China.
Yan AnDepartment of Spine Surgery, Beijing Jishuitan Hospital, Capital Medical University, Beijing, China.
Qingyun LiDepartment of Spine Surgery, Beijing Jishuitan Hospital, Capital Medical University, Beijing, China.
Da HeDepartment of Spine Surgery, Beijing Jishuitan Hospital, Capital Medical University, Beijing, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

BACKGROUND Spinal pedicle screw-rod fixation is widely used, but manual rod bending is time-consuming and prone to contour inconsistencies. Although computer-assisted technologies have been explored, existing systems remain limited by cost, complexity, and insufficient precision. This study evaluated a novel computer-assisted rod design and bending system, with the goal of testing whether computer-assisted rod bending reduces bending plus installation time vs manual bending in unilateral paired cases and to evaluate safety, feasibility, and rod-screw fitting accuracy. MATERIAL AND METHODS A prospective trial enrolled 26 patients (18-75 years) undergoing spinal pedicle screw-rod fixation (≥4 segments) for fractures or degenerative diseases. Twenty patients received unilateral computer-assisted bending (contralateral manual for comparison) and 6 received bilateral assisted bending. The primary outcome was bending plus installation time; secondary outcomes included complications and fitting accuracy. Wilcoxon signed-rank test was used (P<0.05). RESULTS No instrument-related complications were observed (n=26; median age 60.5 years). For 20 unilateral cases, computer-assisted bending (183.3±70.8 seconds) was significantly shorter than manual bending (236.1±119.1 s; mean reduction 52.75 seconds, P=0.017). Subgroup analyses indicated signals of greater time savings in more than 4 segments (93.9 seconds, P=0.039) and BMI of 25 kg/m2 or higher (95.3 seconds, P=0.005), although these were exploratory and not adjusted for multiplicity. CONCLUSIONS The computer-assisted system reduced bending plus installation time vs manual bending, with no instrument-related complications. Subgroup findings were exploratory and require further validation.

Indexed as

Computer-Aided DesignFracture Fixation, InternalSpinal FusionSurgery, Computer-AssistedAdolescentAdultAgedFeasibility StudiesFemaleHumansMaleMiddle AgedPedicle ScrewsProspective StudiesYoung Adult

Identifiers

PMID42675825
PMCPMC13545973

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.