Evidence map›Paper›PMID 42675306›Full record

ArticleSurgical endoscopy2026

Hepaticojejunostomy bile leakage and aberrant biliary anatomy during robotic pancreatoduodenectomy: intraoperative detection and management.

Oskar Swartling, Julia E Menso, Freek Daams, Sebastiaan Festen, Martin C Boonstra, Babs Zonderhuis, Joris Erdmann, Rutger-Jan Swijnenburg, Olivier R Busch, Marc G Besselink and 1 more

Erratum issuedAbstract read
PubMed Publisher
In one paragraph

Article in Surgical endoscopy, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

11 authors.

Oskar SwartlingDepartment of Upper Abdominal Diseases, Karolinska University Hospital, Stockholm, Sweden.ORCID http://orcid.org/0000-0002-3783-1567
Julia E MensoAmsterdam UMC, University of Amsterdam, Department of Surgery, Amsterdam, The Netherlands.
Freek DaamsCancer Center Amsterdam, Amsterdam, The Netherlands.
Sebastiaan FestenDepartment of Surgery, OLVG, Amsterdam, The Netherlands.
Martin C BoonstraCancer Center Amsterdam, Amsterdam, The Netherlands.
Babs ZonderhuisCancer Center Amsterdam, Amsterdam, The Netherlands.
Joris ErdmannAmsterdam UMC, University of Amsterdam, Department of Surgery, Amsterdam, The Netherlands.
Rutger-Jan SwijnenburgAmsterdam UMC, University of Amsterdam, Department of Surgery, Amsterdam, The Netherlands.
Olivier R BuschAmsterdam UMC, University of Amsterdam, Department of Surgery, Amsterdam, The Netherlands.
Marc G BesselinkAmsterdam UMC, University of Amsterdam, Department of Surgery, Amsterdam, The Netherlands. m.g.besselink@amsterdamUMC.nl.
* for HPB-Amsterdam

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundBile leakage from the hepatico-jejunostomy (HJ) is a rare but potentially lethal complication during robotic pancreatoduodenectomy (RPD). The rate of intraoperatively detected bile leakage from the HJ and aberrant biliary anatomy during RPD and its optimal management remains unclear.

methodsThis retrospective and exploratory cohort study included all adult patients undergoing RPD at a single high-volume center (December 2018-March 2025). Standardized operating reports were reviewed regarding: (a) intraoperative bile leakage observed during the routinely performed 'HJ gauze test,' (b) multiple HJ anastomoses, (c) joined bile ducts, or (d) placement of a HJ stent. Bile leakage was managed intraoperatively by additional direct sutures or, if not deemed safe, by anchoring sutures between the jejunum and the hilar plate. Only ISGLS bile leakage grade B/C was included.

resultsOverall, 238 patients undergoing RPD were included. The routinely performed intraoperative 'HJ gauze test' detected bile leakage in 21 (9%) patients, all of whom underwent intraoperative surgical repair: 13 (62%) direct sutures and 8 (38%) anchoring sutures to the hilar plate. In these patients, postoperative bile leakage occurred in 3/21 (14%) patients with 0/21 (0%) mortality. Overall, 5 (2%) patients received two HJs, and 8 (3%) patients received a stent in the HJ with 0/11 (0%) bile leakage. Patients with intraoperative findings of bile leakage had a non-significant higher rate of postoperative bile leakage (3 patients [14%] vs 12 patients [6%]) (OR 2.83, 95% CI 0.47 to 11.91, Fisher's exact test p = 0.12).

conclusionRoutine use of the 'HJ gauze test' during RPD may be useful to detect intraoperative bile leakage, with similar outcomes after intraoperative repair (either with direct sutures or anchoring sutures). Non-standard HJ constructions and bile duct anatomy variants were rare.

Indexed as

Bile leakageHepaticojejunostomyPancreatoduodenectomyRobotic assistedWhipple

Identifiers

PMID42675306

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.