Evidence map›Paper›PMID 42675098›Full record

ArticleScientific reports2026

Development and evaluation of a multi-axis loading simulator for the spine, pelvis, and lumbosacral region.

Toni Wendler, Robin Heilmann, Hannah Müller, Jean-Pierre Fischer, Andreas Höch, Christian Kleber, Christoph-E Heyde, Stefan Schleifenbaum

Abstract read
In one paragraph

Article in Scientific reports, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Toni WendlerDepartment of Orthopedic, Trauma and Plastic Surgery, University of Leipzig Medical Center, Liebigstraße 20, D-04103, Leipzig, Germany. toni.wendler@medizin.uni-leipzig.de.ORCID 0000-0001-7890-178X
Robin HeilmannDepartment of Orthopedic, Trauma and Plastic Surgery, University of Leipzig Medical Center, Liebigstraße 20, D-04103, Leipzig, Germany.
Hannah MüllerDepartment of Orthopedic, Trauma and Plastic Surgery, University of Leipzig Medical Center, Liebigstraße 20, D-04103, Leipzig, Germany.
Jean-Pierre FischerDepartment of Orthopedic, Trauma and Plastic Surgery, University of Leipzig Medical Center, Liebigstraße 20, D-04103, Leipzig, Germany.
Andreas HöchDepartment of Orthopedic, Trauma and Plastic Surgery, University of Leipzig Medical Center, Liebigstraße 20, D-04103, Leipzig, Germany.
Christian KleberDepartment of Orthopedic, Trauma and Plastic Surgery, University of Leipzig Medical Center, Liebigstraße 20, D-04103, Leipzig, Germany.
Christoph-E HeydeDepartment of Orthopedic, Trauma and Plastic Surgery, University of Leipzig Medical Center, Liebigstraße 20, D-04103, Leipzig, Germany.
Stefan SchleifenbaumDepartment of Orthopedic, Trauma and Plastic Surgery, University of Leipzig Medical Center, Liebigstraße 20, D-04103, Leipzig, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The treatment of injuries and disorders of the pelvis, lumbar spine and lumbosacral junction remains challenging due to rising case numbers, complex anatomy and high biomechanical demands. Despite advances in surgical techniques and implant design, problems regarding stability and long-term functionality persist, requiring individualized solutions and a thorough biomechanical assessment. Biomechanical studies are essential for assessing implant performance under physiological conditions. This study therefore aims to develop and validate a versatile biomechanical loading simulator capable of reproducing common test protocols, improving the comparability of results and enabling a systematic evaluation of innovative implant and treatment concepts. A loading simulator with three active degrees of freedom (driven by controlled servo motors) and two passive degrees of freedom (low-friction linear slide bearings) was developed. Five pelvic specimens with an intact lumbar spine up to L2 were first subjected to a range-of-motion (ROM) analysis and subsequently to cyclic dynamic loading to test the functionality of the simulator. The ROM analysis resulted in mean absolute deviations (MAD) of less than 7.50 N for all translational degrees of freedom (DOF) and less than 0.87 Nm for the two unloaded rotational DOF. The maximum moment in the loading direction deviated by a MAD of less than 0.18 Nm. The cyclic loading protocol was achieved in the vertical force direction (60% body weight (BW)) with a MAD of less than 0.76% BW. The maximum and minimum moments to be applied in extension-flexion (± 5 Nm) were realized with a MAD of less than 0.23 Nm. In summary, the simulator developed demonstrates a high degree of accuracy, reproducibility and flexibility. It therefore provides a suitable platform for the biomechanical investigation of implants and stabilization concepts in the pelvic and spinal regions and offers a promising basis for future experimental studies.

Indexed as

Lumbar VertebraeLumbosacral RegionPelvisSpineBiomechanical PhenomenaHumansRange of Motion, ArticularWeight-BearingBiomechanical loading simulatorBiomechanical testingImplant investigation of spine and pelvisMultiaxial loadingRange-of-motion spine

Identifiers

PMID42675098
PMCPMC13530234

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked