Development and implementation of an automated micrometric bone distraction system based in a fuzzy logic controller for an Aybar-type external fixator.

Joao Marcelo Valdivia De La Gala, Andrea Sophia Valladares Chavez, Carlos Hernan Inga Espinoza

Abstract read
PubMed Publisher
In one paragraph

Article in Medical & biological engineering & computing, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Joao Marcelo Valdivia De La GalaSchool of Mechatronics Engineering, Universidad Peruana de Ciencias Aplicadas, Lima, 15088, Lima, Perú. u202018990@upc.edu.pe.ORCID http://orcid.org/0009-0001-3590-3213
Andrea Sophia Valladares Chavez *School of Mechatronics Engineering, Universidad Peruana de Ciencias Aplicadas, Lima, 15088, Lima, Perú.ORCID http://orcid.org/0009-0006-8614-6538
Carlos Hernan Inga Espinoza *School of Mechatronics Engineering, Universidad Peruana de Ciencias Aplicadas, Lima, 15088, Lima, Perú.ORCID http://orcid.org/0000-0001-8680-6846

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Bone distraction is a widely applied orthopedic procedure based on Ilizarov's tension-stress principle, which requires high precision and accuracy to guarantee successful bone regeneration. In many low resource locations, the Aybar-type external fixator is the only viable treatment option due to its low cost and accessibility. However, its manual procedure introduces human error, reduces precision, and compromises treatment outcomes. To address this problem, this study develops and implements an automated micrometric distraction system for an Aybar-type fixator, aiming to provide a low cost yet highly accurate alternative, particularly focused on pediatric patients, for whom precision is critical to ensure proper callus formation and bone growth. Four control strategies were designed and evaluated: an ON-OFF controller, a Proportional-Integral (PI) controller, a Linear Quadratic Integrator (LQI), and a Fuzzy Logic Controller (FLC). The mechanical platform integrates a Direct Current (DC) motor, encoder, and worm gear with 1.25 mm pitch, while simulations and experimental tests were performed under two distraction regimens: 1 mm/day in four increments and 1 mm/day in sixty increments. Results indicate that the FLC achieves the best performance in coarse step elongation, while the LQI provides superior results in high-resolution protocols. These findings demonstrate that it is possible to enhance the precision and reproducibility of the Aybar external fixator through low cost automation. The proposed solution contributes to improving treatment quality for pediatric patients in contexts where advanced imported systems are unavailable, filling a critical gap between affordability and clinical efficacy.

Indexed as

Aybar-type external fixatorBone distractionControl systemDC MotorFuzzy logic controllerLimb lengtheningPediatric orthopedics

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked