ArticleMedical & biological engineering & computing2026
Development and implementation of an automated micrometric bone distraction system based in a fuzzy logic controller for an Aybar-type external fixator.
Article in Medical & biological engineering & computing, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Bone distraction is a widely applied orthopedic procedure based on Ilizarov's tension-stress principle, which requires high precision and accuracy to guarantee successful bone regeneration. In many low resource locations, the Aybar-type external fixator is the only viable treatment option due to its low cost and accessibility. However, its manual procedure introduces human error, reduces precision, and compromises treatment outcomes. To address this problem, this study develops and implements an automated micrometric distraction system for an Aybar-type fixator, aiming to provide a low cost yet highly accurate alternative, particularly focused on pediatric patients, for whom precision is critical to ensure proper callus formation and bone growth. Four control strategies were designed and evaluated: an ON-OFF controller, a Proportional-Integral (PI) controller, a Linear Quadratic Integrator (LQI), and a Fuzzy Logic Controller (FLC). The mechanical platform integrates a Direct Current (DC) motor, encoder, and worm gear with 1.25 mm pitch, while simulations and experimental tests were performed under two distraction regimens: 1 mm/day in four increments and 1 mm/day in sixty increments. Results indicate that the FLC achieves the best performance in coarse step elongation, while the LQI provides superior results in high-resolution protocols. These findings demonstrate that it is possible to enhance the precision and reproducibility of the Aybar external fixator through low cost automation. The proposed solution contributes to improving treatment quality for pediatric patients in contexts where advanced imported systems are unavailable, filling a critical gap between affordability and clinical efficacy.
Indexed as
Identifiers
42671768What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.