Evidence map›Paper›PMID 42671518›Full record

ArticleOdontology2026

The effect of contamination stage and adhesive strategy on the durability of repair bond strength of blood-saliva contaminated aged composite resin.

Cemile Yılmaz, İsmail Haktan Çelik

Abstract read
PubMed Publisher
In one paragraph

Article in Odontology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Cemile YılmazDepartment of Restorative Dentistry, Faculty of Dentistry, Afyonkarahisar Health Sciences University, Afyonkarahisar, Turkey. dt.cemileyilmaz@gmail.com.ORCID http://orcid.org/0000-0002-7780-079X
İsmail Haktan ÇelikDepartment of Paediatric Dentistry, Faculty of Dentistry, Afyonkarahisar Health Sciences University, Afyonkarahisar, Turkey.ORCID http://orcid.org/0000-0003-1662-3790

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This study evaluated whether the stage of contamination (before vs. after adhesive polymerization) and the application strategy of a universal adhesive (GLUMA Bond Universal, Kulzer, Hanau, Germany) used in total-etch (TE) or self-etch (SE) mode affect the durability of repair shear bond strength (RSBS) in aged composite after immediate storage (24 h) and artificial aging (10.000 thermocycles). One hundred twenty composite specimens were thermocycled (5.000 cycles) and assigned to 12 groups based on contamination stage (control, pre-adhesive, post-adhesive), adhesive strategy (TE or SE), and aging period (24 h or 10.000 cycles). A fresh blood/saliva mixture was applied for 1 min and rinsed. In post-adhesive groups, re-bonding was performed, with additional re-etching in the TE subgroup. RSBS was measured at a crosshead speed of 1 mm/min. Data were analyzed by three-way robust ANOVA based on 20% trimmed means (α = 0.05). Effect sizes were estimated using bootstrap partial eta squared (η²p) with 95% confidence intervals. Failure modes were analyzed using Fisher's Exact Test. All main effects were significant: contamination stage (η²p = 0.191, 95% CI: 0.093-0.309), adhesive strategy (η²p = 0.360, 95% CI: 0.263-0.478), and aging period (η²p = 0.805, 95% CI: 0.799-0.838) (all p ≤ 0.001). Significant interactions emerged between contamination stage and aging (p = 0.020, η²p = 0.070, 95% CI: 0.012-0.161) and between adhesive strategy and aging (p = 0.001, η²p = 0.133, 95% CI: 0.047-0.254). The three-way interaction was not significant (p = 0.078). Pre-adhesive contamination significantly reduced bond strength compared to the control and post-adhesive conditions (p < 0.001). TE showed higher RSBS than SE (p < 0.001), whereas aging reduced RSBS (p = 0.001). The highest RSBS was observed in the control + TE + 24 h group (31.11 ± 1.32 MPa), and the lowest in the pre-adhesive + SE + 10.000 TC group (5.33 ± 0.56 MPa). Failure mode distribution shifted from cohesive to adhesive after aging. Re-bonding after post-adhesive contamination restored bond strength to control levels. In conclusion, pre-adhesive blood/saliva contamination is most detrimental to repair durability; the total-etch protocol produced higher RSBS values than the self-etch protocol, although both strategies demonstrated significant degradation after thermal aging.

Indexed as

BloodComposite ResinsDental BondingDental Stress AnalysisHumansMaterials TestingShear StrengthTime FactorsComposite ResinsBlood-Saliva contaminationDecontaminationRepair shear bond strengthThermal cyclingUniversal adhesive

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.