ArticleMedical physics2026
Multi-modal direct LINAC parameter prediction for pancreatic VMAT: An optimization-free approach.
Article in Medical physics, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
Abstract
backgroundPancreatic cancer Volumetric Modulated Arc Therapy (VMAT) planning presents a significant dosimetric challenge due to the high-dose gradients required to spare adjacent, radiosensitive organs at risk (OARs) like the stomach and duodenum. This anatomical complexity has limited the scope of automated planning for this site. Broadly, while deep learning (DL) has been introduced to streamline treatment planning, most existing models only predict intermediate outputs, such as dose distributions or fluence maps, which still necessitate a subsequent, computationally expensive inverse optimization step on a treatment planning system. PURPOSE: To address these challenges, we aim to develop an optimization-free fully automated VMAT planning framework for pancreatic cancer. As a key component of this system, this study introduces a DL model designed to directly generate machine parameters from dose distributions and anatomical contours.
methodsA total of 200 vmat plans for pancreatic cancer (prescription: 42 Gy in 15 fractions) were retrospectively collected. The dataset was randomly split into training (n = 170), validation (n = 10), and testing (n = 20) sets. The proposed Multi-modal, Attention & Transformer-Enhanced U-Net (MATE-UNet) utilizes beam's-eye-view (BEV) projections of the reference dose distribution and anatomical contours to directly predict machine-executable multi-leaf collimator (MLC) apertures and Monitor Units (MUs). The proposed model was benchmarked against baseline U-Nets (using contour-only, dose-only, and combined inputs) on the testing set. Model accuracy was assessed using the Dice Similarity Coefficient (DSC) for MLC and Mean Absolute Error (MAE) for MU, while plan quality was evaluated using clinical dose-volume histogram (DVH) metrics and Conformity Index (CI), Homogeneity Index (HI), and Gradient Index (GI).
resultsMATE-UNet achieved a clinical acceptance rate of 100% (20/20), compared to 70% for the best-performing baseline model. In terms of prediction accuracy, the proposed model achieved a DSC of 0.9553 ± 0.0042 for MLC apertures and an MAE of 1.960 ± 0.396 for MU. Dosimetric evaluation demonstrated that, relative to the reference plans, MATE-UNet maintained comparable target coverage, CI (0.773), and HI (0.100), while achieving a significantly improved GI (3.732, p < 0.05). Furthermore, MATE-UNet significantly reduced the V
conclusionsThis study demonstrates the feasibility of MATE-UNet for the direct prediction of VMAT machine parameters without iterative optimization. By leveraging multi-modal BEV inputs and a Transformer-enhanced architecture, the proposed framework represents a valuable step toward bridging the gap between dose distributions and clinically usable treatment plans. Although an additional normalization step is required to determine the absolute MUs, MATE-UNet has the potential to serve as a downstream component of a future fully automated anatomy-to-plan pipeline.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.