Evidence map›Paper›PMID 42667626›Full record

Trial reportThe international journal of medical robotics + computer assisted surgery : MRCAS2026

Efficacy and Safety Analysis of Single-Port Robotic Assisted Cholecystectomy Using a Novel Surgical Platform: A Bicentre, Single-Arm, Prospective Phase II Clinical Study.

Chao Jing, Kun Liu, Guowei Zhang, Hongwei Wu, Zhe Jia, Guoxin Li, Yaping Zhao, Zhongtao Zhang, Wei Guo

Abstract readClinical Trial, Phase IIMulticenter Study
In one paragraph

Trial report in The international journal of medical robotics + computer assisted surgery : MRCAS, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Trial
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Chao JingDepartment of General Surgery, Beijing Friendship Hospital, Capital Medical University, Beijing, China.ORCID https://orcid.org/0000-0002-2146-3448
Kun LiuDepartment of General Surgery, Beijing Friendship Hospital, Capital Medical University, Beijing, China.ORCID https://orcid.org/0000-0001-7608-1335
Guowei ZhangDepartment of General Surgery, Nanfang Hospital, Southern Medical University, Guangzhou, China.ORCID https://orcid.org/0000-0002-1487-6340
Hongwei WuDepartment of General Surgery, Beijing Friendship Hospital, Capital Medical University, Beijing, China.
Zhe JiaDepartment of General Surgery, Beijing Friendship Hospital, Capital Medical University, Beijing, China.
Guoxin LiDepartment of General Surgery, Nanfang Hospital, Southern Medical University, Guangzhou, China.ORCID https://orcid.org/0000-0003-2773-7048
Yaping ZhaoShanghai Microport Medbot (Group) Co. Ltd, Shanghai, China.
Zhongtao ZhangDepartment of General Surgery, Beijing Friendship Hospital, Capital Medical University, Beijing, China.ORCID https://orcid.org/0000-0002-8070-7932
Wei GuoDepartment of General Surgery, Beijing Friendship Hospital, Capital Medical University, Beijing, China.

Funding

National key clinical specialist construction Programs, Beijing Hospitals Authority Clinical Medicine Development of special funding support XMLX202102National Key Technologies R&D Program 2015BAI13B09the National Key Technologies R&D Program of China 2017YFC0110904
6 · The paper itself

Abstract

backgroundSingle-port robotic cholecystectomy offers minimally invasive benefits. This trial evaluated the feasibility and safety of a novel system, MicroPort SA-1000.

methodsIn this dual centre, single-arm, prospective study, eligible patients underwent single-port robot-assisted cholecystectomy with MicroPort SA-1000. The primary endpoint was the completion rate, while secondary endpoints included estimated blood loss, operating time, hospital length of stay and complications.

resultsFrom June 2023 to December 2023, a total of 44 patients from two centres were enrolled, and all patients underwent single-port robot-assisted cholecystectomy without conversion. The median EBL was 10 mL (range 5-200 mL). The total operative time was 88.43 ± 25.87 minutes. The median LOS was 2.5 days (range 1-7 days). No serious surgery-related adverse events were observed.

conclusionsThe novel single-port robot demonstrated feasibility and safety in cholecystectomy with effective triangulation, controlled operative time and reduced trauma. Larger studies are needed to validate its performance across different surgical fields.

trial registrationThis study was registered at https://www.chictr.org.cn/showproj.html?proj=258677 (ChiCTR2500107401).

Indexed as

CholecystectomyCholecystectomy, LaparoscopicRobotic Surgical ProceduresAdultAgedBlood Loss, SurgicalEquipment DesignFeasibility StudiesFemaleHumansLength of StayMaleMiddle AgedOperative TimeProspective StudiesTreatment Outcomecholecystectomyrobotic‐assisted surgerysafetysingle‐port laparoscopy robotsurgical outcome

Identifiers

PMID42667626
PMCPMC13525855

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked