Evidence map›Paper›PMID 42665936›Full record

ArticleJournal of applied clinical medical physics2026

A Monte Carlo based dose verification tool for an HDR Ir-192 brachytherapy source and its evaluation on extremity malignancies.

Peixiong Li, Chi Wah Kong, Rihui Zhang, Dejun Zhou, Chenyu Huang, Tin Lok Chiu, Pak Hang Nam, Chi To Yung, Tien Yee Chang, Siu Ki Yu and 1 more

Abstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Peixiong LiDepartment of Medical Physics, Hong Kong Sanatorium & Hospital, Hong Kong, Hong Kong.
Chi Wah KongDepartment of Medical Physics, Hong Kong Sanatorium & Hospital, Hong Kong, Hong Kong.
Rihui ZhangMedical Physics Graduate Program, Duke Kunshan University, Kunshan, Jiangsu, P.R. China.
Dejun ZhouDepartment of Medical Physics, Hong Kong Sanatorium & Hospital, Hong Kong, Hong Kong.
Chenyu HuangDepartment of Medical Physics, Hong Kong Sanatorium & Hospital, Hong Kong, Hong Kong.
Tin Lok ChiuDepartment of Medical Physics, Hong Kong Sanatorium & Hospital, Hong Kong, Hong Kong.
Pak Hang NamDepartment of Medical Physics, Hong Kong Sanatorium & Hospital, Hong Kong, Hong Kong.
Chi To YungDepartment of Medical Physics, Hong Kong Sanatorium & Hospital, Hong Kong, Hong Kong.
Tien Yee ChangDepartment of Medical Physics, Hong Kong Sanatorium & Hospital, Hong Kong, Hong Kong.
Siu Ki YuDepartment of Medical Physics, Hong Kong Sanatorium & Hospital, Hong Kong, Hong Kong.
Bin YangDepartment of Medical Physics, Hong Kong Sanatorium & Hospital, Hong Kong, Hong Kong.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundTG-43 formalism dose calculation for brachytherapy with the homogeneous water-based assumption is widely used, which can lead to dose inaccuracy in treatment planning. PURPOSE: Extremity malignancies are also treated with high-dose-rate (HDR)

methodsBrachyPlanCheck was commissioned and validated in both a homogeneous water phantom and a heterogeneous breast phantom. The clinical evaluation included 8 patient-specific lower limb brachytherapy plans, comparing TG-43 and MC calculation using BrachyPlanCheck. Dosimetric differences were evaluated using dose comparisons, gamma index analysis, and dose-volume histogram (DVH) metrics for clinical target volume (CTV) and organ-at-risk (OAR), including bone and skin.

resultsIn commissioning Level 1, MC simulations using BrachyPlanCheck demonstrated point dose agreement within ± 0.9%. Gamma passing rates exceeded 99.9% with criteria 1 mm/1% in commissioning Level 2. In clinical evaluation, TG-43 calculation overestimated CTV V150 by up to 10.50% and CTV D90 by up to 7.25%. OAR doses were generally higher with TG-43, with mean differences of 1.09% for bone D1cc (p =  0.109), 1.38% for bone D0.1cc (p =  0.078), 7.30% for skin D2cc (p =  0.008), and 5.68% for skin D0.1cc (p =  0.008).

conclusionValidated by phantom and patient study, BrachyPlanCheck demonstrated robust performance for independent secondary dose verification. TG-43 calculation overestimated dose to CTV and OAR in extremity malignancy cases compared with BrachyPlanCheck.

Indexed as

Bone NeoplasmsBrachytherapyExtremitiesIridium RadioisotopesMonte Carlo MethodOrgans at RiskPhantoms, ImagingRadiotherapy Planning, Computer-AssistedHumansRadiotherapy DosageRadiotherapy, Intensity-ModulatedIridium-192Iridium Radioisotopesdosimetryextremity malignanciesinterstitial brachytherapylower limbmonte carlosarcoma

Identifiers

PMID42665936
PMCPMC13525196

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.