Evaluation of the environ SRS immobilization mask system for HyperArc: Dosimetric attenuation, dose calculation accuracy, and clinical setup reproducibility.

Adi Robinson, Matthew R Caldwell

Abstract readEvaluation Study
In one paragraph

Article in Journal of applied clinical medical physics, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Adi RobinsonDepartment of Radiation Oncology, AdventHealth Celebration, Celebration, Florida, USA.
Matthew R CaldwellDepartment of Radiation Oncology, AdventHealth Celebration, Celebration, Florida, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundFrameless thermoplastic masks are standard for intracranial stereotactic radiosurgery (SRS), with the Encompass (CQ Medical) widely used on the Varian HyperArc platform. A candidate mask must minimize beam attenuation, permit accurate dose calculation, and enable reproducible setup, yet these are rarely assessed together. Comprehensive comparative data for the proposed Environ (MacroMedics) mask are limited. PURPOSE: To compare the Environ and Encompass masks across three domains: beam attenuation, dose-calculation accuracy under different algorithm and mask-contouring conditions, and interfraction setup reproducibility.

methodsAttenuation was measured with an ionization chamber in a head phantom (TrueBeam, 6 FFF) at seven static gantry angles and a 0°-180° arc, with an estimated measurement uncertainty budget. Planning accuracy was assessed using HyperArc plans on phantom CT for 1-15 mm PTV margins (single-target) and 3/5/7 mm (multi-metastasis), calculated in Eclipse with AAA and Acuros XB (AXB), each with and without the mask in the body contour. Setup reproducibility was analyzed retrospectively from CBCT six-degree-of-freedom corrections (Encompass: 67 fractions/21 patients; Environ: 72 fractions/24 patients). Because repeated fractions are not independent, positioning data were analyzed at the patient level (Mann-Whitney U, Levene's test), by within-patient reproducibility, and with a confirmatory mixed-effects model.

resultsThe Encompass attenuated 1.13% ± 0.59% more than the Environ for static beams (p = 0.002); the arc difference (0.06%) was within uncertainty (∼0.4%, k = 1). The Encompass required mask contouring with AXB for acceptable agreement (2.38% without), whereas the Environ achieved sub-1% AXB agreement without contouring (0.24%). The Environ showed a smaller mean vertical correction (mixed-effects p = 0.016) and reduced within-patient variability in vertical (0.31 vs. 1.25 mm, p < 0.001) and pitch (0.50 vs. 0.99°, p = 0.009); other axes were comparable.

conclusionThe Environ performed comparably or favorably across all three domains, supporting it as a clinically acceptable SRS alternative. It achieved acceptable AXB agreement without mask contouring under the conditions tested, though this depends on institution-specific settings and should be verified locally. The setup-reproducibility advantages, most robust vertically, are hypothesis-generating given the retrospective design and absence of intrafraction data.

Indexed as

Brain NeoplasmsImmobilizationMasksPhantoms, ImagingRadiosurgeryRadiotherapy Planning, Computer-AssistedAlgorithmsHumansOrgans at RiskPatient PositioningRadiometryRadiotherapy DosageRadiotherapy, Intensity-ModulatedReproducibility of ResultsRetrospective StudiesAcurosXBHyperArcimmobilization maskstereotactic radiosurgery