Evidence map›Paper›PMID 42663740›Full record

ArticleJournal of robotic surgery2026

Impact of the force feedback feature on transoral robotic surgery.

Takashi Mukaigawa, Seiya Goto, Kayo Sakamoto, Nobuyuki Sakuma, Takashi Kitani, Sohei Mitani

Abstract read
PubMed Publisher
In one paragraph

Article in Journal of robotic surgery, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Takashi MukaigawaDivision of Head and Neck Surgery, Shizuoka Cancer Center, 1007 Shimonagakubo, Nagaizumi-cho, Sunto-gun, Shizuoka, 411-8777, Japan. t.mukaigawa@scchr.jp.ORCID https://orcid.org/0000-0001-9804-7154
Seiya GotoDivision of Head and Neck Surgery, Shizuoka Cancer Center, 1007 Shimonagakubo, Nagaizumi-cho, Sunto-gun, Shizuoka, 411-8777, Japan.
Kayo SakamotoDivision of Head and Neck Surgery, Shizuoka Cancer Center, 1007 Shimonagakubo, Nagaizumi-cho, Sunto-gun, Shizuoka, 411-8777, Japan.
Nobuyuki SakumaDivision of Head and Neck Surgery, Shizuoka Cancer Center, 1007 Shimonagakubo, Nagaizumi-cho, Sunto-gun, Shizuoka, 411-8777, Japan.
Takashi KitaniDepartment of Otolaryngology, Head and Neck Surgery, Ehime University Graduate School of Medicine, Ehime, Japan.
Sohei MitaniDepartment of Otolaryngology, Head and Neck Surgery, Ehime University Graduate School of Medicine, Ehime, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Transoral robotic surgery (TORS) has become an established minimally invasive approach for treating head and neck cancer. However, the absence of haptic feedback constrains surgeons to rely almost exclusively on visual cues, which may compromise tissue handling and resection accuracy. This study evaluated the effect of force feedback on surgical performance using a robotic system equipped with haptic feedback in a simulated TORS model. Fifteen head and neck surgeons, categorized as experienced or trainees, performed simulated transoral tumor resection using a plant-derived soft tissue phantom. Contact and grasping forces, resection accuracy, and tissue effects were compared between force-feedback-on and force-feedback-off conditions. Across all surgeons, all contact force measures and mean and maximal grasping forces were significantly lower under the feedback-on condition. Mean contact force was 1.59 ± 0.25 N with feedback on versus 2.11 ± 0.29 N with feedback off (P < 0.001), and maximal contact force was 4.32 ± 1.11 N versus 5.86 ± 2.40 N (P = 0.003). A significant feedback-by-experience interaction was observed for maximal contact force (P = 0.021), with a greater reduction among trainees. Force feedback also significantly reduced horizontal and deep margin deviations and tissue charring. Operative time was not significantly affected. Force feedback improved force control and procedural precision overall, with a particularly pronounced effect on limiting excessive peak contact forces among training surgeons. These findings support the potential value of force feedback for more precise and controlled robotic surgery.

Indexed as

FeedbackHead and Neck NeoplasmsRobotic Surgical ProceduresHumansMouthOperative TimeSurgeonsForce feedbackHaptic feedbackRobotic surgerySurgical simulationSurgical trainingTransoral robotic surgery

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked