Evidence map›Paper›PMID 42658460›Full record

ArticleOdontology2026

Bond strength performance of a self-curing bulk-fill restorative system and light-cured restorative systems after aging: an in vitro study.

Larissa Fiorin Arruda, Diana Moreira Gomes Martins, Luan Júlio Ruiz da Silva, Max Pinto da Costa da Rocha, Milton Carlos Kuga, Cristiane de Melo Alencar

Abstract read
PubMed Publisher
In one paragraph

Article in Odontology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Larissa Fiorin ArrudaSchool of Dentistry, University Center of the State of Pará - CESUPA, Belém, PA, Brazil.ORCID http://orcid.org/0009-0004-6746-013X
Diana Moreira Gomes MartinsSchool of Dentistry, University Center of the State of Pará - CESUPA, Belém, PA, Brazil.ORCID http://orcid.org/0009-0001-7137-0733
Luan Júlio Ruiz da SilvaSchool of Dentistry, Department of Restorative Dentistry, São Paulo State University Júlio de Mesquita Filho - UNESP, Araraquara, São Paulo, Brazil.ORCID http://orcid.org/0009-0007-7650-7085
Max Pinto da Costa da RochaSchool of Dentistry, Federal University of Pará - UFPA, Belém, PA, Brazil.
Milton Carlos KugaDepartment of Restorative Dentistry, Araraquara Dental School, São Paulo State University Júlio de Mesquita Filho - UNESP, Araraquara, São Paulo, Brazil.ORCID http://orcid.org/0000-0001-5728-8293
Cristiane de Melo AlencarSchool of Dentistry, University Center of the State of Pará - CESUPA, Belém, PA, Brazil. cristiane_melo_alencar@hotmail.com.ORCID http://orcid.org/0000-0002-0694-6863

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The microtensile bond strength (µTBS) and failure patterns of a self-curing bulk-fill restorative system (STELA, SDI) were investigated and compared with those of a light-cured bulk-fill and a conventional light-cured restorative system following short- and long-term aging in artificial saliva. Forty-eight human teeth were randomly assigned to three groups (n = 16): G1, self-curing bulk-fill restorative system; G2, light-cured bulk-fill restorative system; and G3, conventional light-cured restorative system applied incrementally. Intact restored teeth were stored in artificial saliva for either 24 h or 18 months (n = 8 per condition) and were sectioned only after completion of the respective aging period to obtain five beam-shaped specimens (≈ 0.9 mm²). The tooth was considered the experimental unit. Specimens were stored for either 24 h or 18 months (n = 8 per condition). µTBS was assessed at a crosshead speed of 1 mm/min, and failure modes were determined using stereomicroscopy, with representative samples analyzed by scanning electron microscopy. Data were subjected to two-way ANOVA and Tukey's post hoc test (α = 0.05). Bond strength was significantly influenced by both restorative system and aging time (p < 0.001). A significant interaction between restorative system and aging condition was also detected (p < 0.001). G2 exhibited the lowest µTBS values and a higher prevalence of adhesive failures. In contrast, G1 showed bond strength comparable to G3 and significantly higher than G2. Cohesive failures predominated in G1 and G3, whereas adhesive failures were more frequent in G2. Within the limitations of this in vitro study, the self-curing bulk-fill restorative system demonstrated adhesive performance similar to the conventional restorative system and preserved its relative behavior after aging, under the respective adhesive strategies recommended by the manufacturers.

Indexed as

Composite resinsDental materialsDentin-bonding agentsTensile strength

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.