ArticleMagma (New York, N.Y.)2026
Motion-induced fields near an idealized actively shielded MRI magnet: a reproducible reduced-order framework for scaling and sensitivity from 1.5 to 7 T.
Article in Magma (New York, N.Y.), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
1 author.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeTo present a transparent reduced-order electromagnetic framework for examining how an explicitly specified magnet geometry, movement trajectory, and body-conversion model affect movement-induced field estimates near MRI systems. The framework distinguishes dependencies imposed by the equations from spatial and sensitivity results computed from the field map.
methodsAn idealized actively shielded magnet was represented by primary and opposing coaxial solenoids. A 7-T reference system was calibrated at two axial points; 1.5 T and 3 T cases were then generated by matched-geometry ampere-turn scaling as a controlled thought experiment. Movement-induced dB/dt was calculated from the directional derivative v·∇|B|. The primary whole-trunk screening estimate used an ellipsoidal conversion coefficient of 0.16 V m
resultsAlong the specified axial path, the peak dB/dt at 1.5 m s
conclusionThis reproducible reduced-order framework quantifies how active-shield geometry, movement direction, and body-conversion assumptions shape motion-induced field estimates near an idealized MRI magnet. The calculations expose substantial sensitivity to the body model, shield geometry, and trajectory, providing a transparent basis for education, model verification, and the design of scanner-specific dosimetric studies. Translation to regulatory compliance or operational guidance requires measured or vendor-provided fringe-field maps, anatomically resolved dosimetry, waveform analysis, and local safety procedures.
Indexed as
Identifiers
42658454What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.