ArticleJACC. Advances2026
Optimized Balloon-Expandable Transcatheter Aortic Valve Implantation and Clinical Outcomes.
Article in JACC. Advances, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
14 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundThe expansion of transcatheter aortic valve replacement (TAVR) to younger patients with longer life expectancy requires procedural optimization to enhance long-term valve durability.
objectivesTo evaluate the relationship between fluoroscopic determinants of optimal transcatheter heart valve (THV) implantation-coaxiality, implantation depth, and expansion-and clinical and valve-related outcomes.
methodsIn this cohort study, consecutive patients undergoing transfemoral TAVR with balloon-expandable prostheses (Sapien S3, Sapien S3 Ultra) between February 2014 and June 2022 were included. THV coaxiality, implantation depth, and expansion were assessed in the 3-cusp view following deployment using standardized protocols. Suboptimal implantation was defined as ≥1 unfavorable determinants (coaxiality ≥4.8°, depth ≥6 mm, or underexpansion ≥20%). Outcomes included the modified early safety endpoint, moderate or severe hemodynamic valve deterioration, and stage 2 bioprosthetic valve failure.
resultsAmong 1,032 patients (mean age 81 ± 6 years, 35.1% female), suboptimal THV implantation occurred in 443 (42.9%) patients and was driven by noncoaxial deployment (n = 240, 23.3%), excessive implantation depth (n = 261, 25.3%), and underexpansion (n = 54, 5.2%). Suboptimal implantation was associated with a higher likelihood of the modified early safety endpoint at 30 days (43.3% vs 19.9%; adjusted odds ratio: 3.05; 95% CI: 2.30-4.04) and stage 2 bioprosthetic valve failure at 5 years (subHR: 4.40; 95% CI: 1.25-13.59). Patients with ≥2 determinants demonstrated higher rates of hemodynamic valve deterioration at 5 years (subHR: 3.48; 95% CI: 1.24-9.80).
conclusionsOptimal THV implantation was associated with improved early procedural safety and long-term THV durability in balloon-expandable TAVR. Systematic fluoroscopic assessment of optimized valve implantation may enhance patient outcomes.