ArticleFrontiers in medicine2026
Local anesthetic overdose during nurse-led epidural analgesia due to occlusion alarm misinterpretation: a case report and literature review.
Article in Frontiers in medicine, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Rationale: Epidural analgesia (EA) medication errors are rare but serious adverse events in anesthesia and pain management. Previous literature has predominantly reported errors involving drug types or routes of administration, whereas those caused by infusion devices are uncommon. This case highlights the potential hazard of dose overdose resulting from an abnormal "occlusion" alarm when using a syringe pump for EA bolus. Patient concerns: A 36-year-old male with recurrent hyperlipidemic severe acute pancreatitis, third episode, was admitted to the intensive care unit (ICU). On admission, the pain score was 7/10 (visual analog scale, VAS). Thoracic epidural analgesia (T8-T9) was administered, with continuous infusion and intermittent boluses of a local anesthetic mixture for pain relief. Diagnosis: Extensive sympathetic blockade due to EA local anesthetic overdose, manifested as acute hypotension, tachycardia, and bilateral lower limb numbness after EA bolus administration. Interventions: Given that the patient's pain score was as high as 8/10 on day 4, a 5 ml EA bolus of the analgesic mixture was prescribed. The nurse used a syringe pump for the bolus. Due to high catheter resistance, the pump repeatedly triggered an "occlusion" alarm. The nurse misinterpreted this as no drug infusion and continued the procedure after repeatedly clearing the alarm, ultimately administering approximately 10 ml. Upon recognition, the EA route was immediately closed, and rapid intravenous infusion of 500 ml of compound sodium chloride solution was administered, along with intravenous norepinephrine at 0.2 μg/kg/min via a syringe pump. Outcomes: Hemodynamics recovered within 10 min, and sensation in both lower limbs gradually returned to normal within 30 min. The patient was transferred to another department 5 days after the event, with no long-term sequelae. Lessons: Misinterpretation of a syringe pump's "occlusion" alarm during nurse-led epidural bolus administration can lead to local anesthetic overdose. This case underscores the need for improved training on device characteristics and alarm management.