Evidence map›Paper›PMID 42656105›Full record

ArticleSheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi2026

[Research on electrooculography artifact removal from electroencephalography signals based on frequency slice wavelet transform].

Haoyu Fu, Mingfu Zhao, Lurui Wang, Bin Tang, Chen Xue, Yuanyuan Chen

Abstract readEnglish Abstract
In one paragraph

Article in Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Haoyu FuSchool of Electrical and Electronic Engineering, Chongqing University of Technology, Chongqing 400054, P. R. China.
Mingfu ZhaoSchool of Electrical and Electronic Engineering, Chongqing University of Technology, Chongqing 400054, P. R. China.
Lurui WangSchool of Computer Science and Engineering, Chongqing University of Technology, Chongqing 400054, P. R. China.
Bin TangSchool of Electrical and Electronic Engineering, Chongqing University of Technology, Chongqing 400054, P. R. China.
Chen XueSchool of Electrical and Electronic Engineering, Chongqing University of Technology, Chongqing 400054, P. R. China.
Yuanyuan ChenSchool of Electrical and Electronic Engineering, Chongqing University of Technology, Chongqing 400054, P. R. China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

To address the strong contamination of single-channel electroencephalography (EEG) signals by electrooculography (EOG) artifacts during acquisition, this paper proposes an EOG artifact suppression method based on an improved frequency slice wavelet transform (FSWT). First, the EEG signal is adaptively decomposed into frequency-slice components using FSWT. Based on the low-frequency energy bursts induced by eye blinks, a robust median absolute deviation (MAD)-based threshold is used to localize artifact-contaminated intervals. Subsequently, only within the detected artifact-contaminated intervals, the dominant low-frequency range of eye-blink artifacts (0.8~3.5 Hz) is used as a prior reference, and adaptive local time-frequency masking is applied to the corresponding frequency components to reduce excessive removal of low-frequency components in normal EEG signals. Finally, the cleaned EEG signal is reconstructed via inverse FSWT, forming a three-stage artifact-removal framework of "detection-masking-reconstruction". Experiments were conducted on the publicly available semi-simulated Klados dataset using signal-to-noise ratio improvement (ΔSNR) and band energy retention rate as evaluation metrics. In addition, the applicability of the proposed method was validated using self-collected single-channel EEG data acquired under real-world conditions. Results showed that the proposed method achieved mean ΔSNR values of (2.81 ± 2.80) dB for all contaminated samples (

Indexed as

ArtifactsElectroencephalographyElectrooculographySignal Processing, Computer-AssistedWavelet AnalysisAlgorithmsBlinkingHumansSignal-To-Noise Ratioelectrooculography artifact reconstructionelectrooculography artifact removalfrequency slice wavelet transformlocal time-frequency maskingsingle-channel electroencephalography

Identifiers

PMID42656105
PMCPMC13519815

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.