ArticleSensors (Basel, Switzerland)2026
Development of a Milli-Kelvin Thermostatic Bath for High-Precision Temperature Sensor Calibration.
Article in Sensors (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors.
Funding
Abstract
For most temperature sensors, measurement traceability must be established via a comparison method within a thermostatic environment. To address the limitations of domestic constant temperature baths in meeting the calibration requirements for high-precision temperature sensors in fields such as semiconductors, a thermostatic bath device with milli-kelvin (mK) level temperature control capability has been developed. First, a novel system scheme was designed to create a sub-cooled condition using a refrigeration machine, while temperature balance was maintained by adjusting the heating power. Second, a high-precision temperature measurement module was designed using a thermistor sensor and a resistance ratio measurement method; measurement accuracy was improved by employing a bidirectional constant current source. Finally, an optimized temperature control logic was proposed to achieve rapid temperature regulation. Experimental results demonstrate that the device operates effectively within a (5-50) °C range, with stability better than 0.003 °C/h and uniformity superior to 0.003 °C. The device has been calibrated by a professional organization and meets the verification requirements for high-precision temperature sensors.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials