Evidence map›Paper›PMID 42655487›Full record

ArticleSensors (Basel, Switzerland)2026

Multi-Sensor Spatiotemporal Feature Fusion for Early Warning of Cable Fires in Power Cable Tunnels.

Mingming Wang, Dong Li, Xiaoyun Sun, Haiqing Zheng

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Mingming WangHebei Provincial Collaborative Innovation Center of Transportation Power Grid Intelligent Integration Technology and Equipment, Shijiazhuang Tiedao University, Shijiazhuang 050043, China.
Dong LiSchool of Electrical and Electronic Engineering, Shijiazhuang Tiedao University, Shijiazhuang 050043, China.
Xiaoyun SunSchool of Electronic and Control Engineering, North China Institute of Aerospace Engineering, Langfang 065000, China.
Haiqing ZhengHebei Provincial Collaborative Innovation Center of Transportation Power Grid Intelligent Integration Technology and Equipment, Shijiazhuang Tiedao University, Shijiazhuang 050043, China.ORCID 0000-0001-7677-2726

Funding

Hebei Provincial Science and Technology Program 262Y5001D
6 · The paper itself

Abstract

Power cable tunnels are typical enclosed cable-routing spaces in which cable overheating, insulation aging, and partial discharge may gradually develop into fire hazards. During the early stage of cable fires, abnormal sensor responses are often weak, localized, and continuously evolving, which increases the difficulty of early warning based on a single sensor or a single temporal feature. Motivated by cable fire early warning in power cable tunnels, this study uses cable-fire records from a publicly available indoor EN 54 fire-test-room dataset with distributed multi-sensor nodes to evaluate the proposed model under controlled laboratory conditions. In monitoring scenarios with fixed sensor nodes, temporal-only modeling methods often struggle to simultaneously characterize short-term variations, temporal evolution, and spatial differences in node responses. To address this limitation, this study proposes a multi-sensor spatiotemporal feature fusion model that integrates a gated recurrent unit (GRU), a Modern Temporal Convolutional Network (ModernTCN), and an enhanced graph convolutional network (GCN+). The proposed model adopts the ModernTCN as the temporal modeling backbone. A GRU module is introduced at the front end to encode local fluctuations and short-term continuous changes between consecutive time steps, while GCN+ is embedded at the intermediate feature stage of the backbone to model spatial correlations and cross-node coordinated responses among fixed sensor nodes. Experimental results show that the proposed model achieves strong classification performance in the cable fire early warning discrimination task, with a test accuracy of 0.9884 and a false negative rate (FNR) reduced to 0.0150. The comparative experimental results indicate that the proposed model achieves better overall performance than typical temporal baseline models. The ablation study further shows that, under the experimental settings of this study, the introduction of GRU and GCN+ leads to overall improvements in the main evaluation metrics, suggesting that both modules provide a certain enhancement to the cable fire early warning discrimination performance of the ModernTCN backbone.

Indexed as

cable fire early warningmulti-sensor data fusionpower cable tunnelspatial relationship modeling among sensor nodesspatiotemporal fusion

Identifiers

PMID42655487
PMCPMC13517850

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.