Evidence map›Paper›PMID 42655474›Full record

ArticleSensors (Basel, Switzerland)2026

Phantom-Free Geometric Refinement for Industrial CBCT Using Physical Constraints and a Normalized Low-Rank Projection Prior.

Yanxu Sun, Xingyuan Bian, Igor A Konyakhin, Junning Cui

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Yanxu SunCenter of Ultra-Precision Optoelectronic Instrument Engineering, Harbin Institute of Technology, Harbin 150080, China.ORCID 0009-0004-7626-1562
Xingyuan BianCenter of Ultra-Precision Optoelectronic Instrument Engineering, Harbin Institute of Technology, Harbin 150080, China.
Igor A KonyakhinHigher School of Engineering and Technology, ITMO University, Kronverksky Pr. 49, Bldg. A, St. Petersburg 197101, Russia.
Junning CuiCenter of Ultra-Precision Optoelectronic Instrument Engineering, Harbin Institute of Technology, Harbin 150080, China.ORCID 0000-0002-4418-8936

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Geometric misalignment degrades industrial cone-beam computed tomography (CBCT), particularly when a dedicated calibration phantom cannot be deployed during object acquisition. This study presents a three-stage, scan-specific geometric refinement framework that searches a bounded five-coordinate correction space around a nominal geometry. Coarse candidates are screened using the normalized residual between a geometry-corrected center-of-mass trajectory and its best-fitting low-order periodic model. Translation- and rotation-dominant coordinates are then refined within system-specific physical bounds, and an energy-normalized nuclear-norm score of corrected row-wise sinograms is used for local correlation refinement. The periodic and low-rank terms are treated as object-dependent surrogate objectives rather than as standalone guarantees of physical parameter identifiability. An exact-ASTRA implementation check using a Shepp-Logan volume verified the detector-plane reindexing convention: applying the injected correction reduced valid-mask projection discrepancy to 35.2%, 13.7%, and 8.66% of the uncorrected values for small, medium, and large perturbations, respectively, with round-trip resampling NRMSE of 0.022-0.023 and a mean valid fraction of 98.4%. Three industrial datasets acquired with horizontal gantry CT, temperature-stage in situ CT, and vertical micro-CT provided comparative reconstruction evidence. In addition, a controlled reduced-resolution industrial object reprojection benchmark was used for direct comparison with MI-PSO, PR, and a stability-regularized implementation of the public epipolar-consistency formulation (Open-ECC-R). Over 20 fixed-ROI axial slices, Open-ECC-R increased the mean SSIM from 0.6852 ± 0.0454 for the uncalibrated reconstruction to 0.8450 ± 0.0155 and reduced the NRMSE from 0.5180 ± 0.0526 to 0.1671 ± 0.0125. The proposed method achieved the highest mean SSIM of 0.9933 ± 0.0002 and the lowest NRMSE of 0.0321 ± 0.0009. For the Bluetooth earphone dataset, local sagittal and axial MTF

Indexed as

center-of-mass trajectoryindustrial cone-beam CTnormalized nuclear normphantom-free geometric refinementphysical constraintsprojection reindexing

Identifiers

PMID42655474
PMCPMC13517192

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.