Evidence map›Paper›PMID 42654693›Full record

ArticleMaterials (Basel, Switzerland)2026

Performance Enhancement of the Passive Heat Exchanger in the MNTZV-159 Metal Hydride Storage System Using Triply Periodic Minimal Surface (TPMS) Structures.

Šimon Hudák, Marián Lázár, Gabriela Ižaríková, Tomáš Brestovič, Natália Jasminská, Peter Čurma, Romana Dobáková, Peter Milenovský

Abstract read
In one paragraph

Article in Materials (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Šimon HudákDepartment of Power Engineering, Faculty of Mechanical Engineering, Technical University of Košice, 04200 Košice, Slovakia.
Marián LázárDepartment of Power Engineering, Faculty of Mechanical Engineering, Technical University of Košice, 04200 Košice, Slovakia.ORCID 0000-0003-1188-3016
Gabriela IžaríkováDepartment of Applied Mathematics and Informatics, Faculty of Mechanical Engineering, Technical University of Košice, 04200 Košice, Slovakia.
Tomáš BrestovičDepartment of Power Engineering, Faculty of Mechanical Engineering, Technical University of Košice, 04200 Košice, Slovakia.ORCID 0000-0002-4557-4230
Natália JasminskáDepartment of Power Engineering, Faculty of Mechanical Engineering, Technical University of Košice, 04200 Košice, Slovakia.ORCID 0000-0002-0926-1296
Peter ČurmaDepartment of Power Engineering, Faculty of Mechanical Engineering, Technical University of Košice, 04200 Košice, Slovakia.ORCID 0009-0007-2981-6109
Romana DobákováDepartment of Power Engineering, Faculty of Mechanical Engineering, Technical University of Košice, 04200 Košice, Slovakia.ORCID 0000-0003-0216-5151
Peter MilenovskýDepartment of Power Engineering, Faculty of Mechanical Engineering, Technical University of Košice, 04200 Košice, Slovakia.ORCID 0009-0008-5667-4895

Funding

Internal grant SjF, TUKE IVG-26-03KEGA granting angency KEGA 031TUKE-4/2025Slovak Research and Development Agency APVV-21-0274Slovak Research and Development Agency APVV-23-0266VEGA granting agency VEGA 1/0587/25
6 · The paper itself

Abstract

Low thermal conductivity of metal hydride beds significantly limits the hydrogen absorption kinetics and performance of metal hydride storage systems. This study presents a new design of a passive internal heat exchanger for a certified MNTZV-159 low-pressure hydrogen storage tank using the Triply Periodic Minimal Surface (TPMS) structures. The parametric improvement in the design of a cylindrical Diamond TPMS-based geometry was performed by applying various cell dimensions, arc counts, and wall thicknesses while maintaining the original volume of the heat exchanger. The analysed configuration was subsequently evaluated through three-dimensional numerical heat-transfer simulations conducted in ANSYS CFX. Compared with the original finned heat exchanger, the TPMS-based design reduced the average metal hydride temperature from 107.7 °C to 86.2 °C and the maximum temperature from 130.9 °C to 114.0 °C. The improved temperature uniformity enhanced the heat removal from the hydride bed and created more favourable conditions for hydrogen absorption. The results demonstrated that TPMS structures constitute a promising solution for improving passive thermal management in metal hydride hydrogen storage systems while maintaining the storage capacity of the vessel.

Indexed as

heat exchangerhydrogenmetal hydridestorage systemTPMS structures

Identifiers

PMID42654693
PMCPMC13514832

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.