Evidence map›Paper›PMID 42654578›Full record

ArticleMaterials (Basel, Switzerland)2026

Experimental Investigation on Hybrid Steel-Grout Vertical Joints with Steel Anchor Rings for Precast Concrete Shear Walls.

Zongchang Li, Bo Cui, Xiaolei Han, Zixiang Peng, Zinan Wu

Abstract read
In one paragraph

Article in Materials (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Zongchang LiSchool of Civil Engineering & Transportation, South China University of Technology, Guangzhou 510641, China.
Bo CuiSchool of Civil Engineering & Transportation, South China University of Technology, Guangzhou 510641, China.
Xiaolei HanSchool of Civil Engineering & Transportation, South China University of Technology, Guangzhou 510641, China.
Zixiang PengChina Construction Fourth Engineering Bureau Corp., Ltd., Guangzhou 510665, China.
Zinan WuSchool of Civil Engineering & Transportation, South China University of Technology, Guangzhou 510641, China.ORCID 0000-0002-6606-5750

Funding

China Postdoctoral Science Foundation 2024M760958Department of Science and Technology of Guangdong Province 2026A1515011108
6 · The paper itself

Abstract

Vertical joints are commonly required in precast concrete shear walls when large wall panels are divided for fabrication, transportation, and erection. To reduce on-site work and improve assembly efficiency, this study proposes and investigates a hybrid steel-grout vertical joint, namely a steel-anchor-ring grouted connection, which uses embedded threaded sleeves, steel anchor rings, an inserted vertical bar, and high-strength grout to transfer shear between adjacent wall panels. Monotonic direct shear tests, cyclic shear tests under normal tension and compression, and cyclic loading tests on precast shear wall specimens were conducted to investigate its mechanical behavior. The load-slip behavior, observed interface debonding, and final shank fracture in the direct shear tests suggested that grout-panel interface bond contributed substantially to the pre-peak response, whereas anchor-ring action became increasingly important after bond degradation. Comparison of the cyclic shear specimens suggested that normal tension promoted interface opening and bond degradation, leading to slip-dominated behavior, whereas normal compression enhanced interface contact and post-peak stability. For the specimens tested, the measured-to-calculated resistance ratios based on the code-based expression were 1.97-2.70 under direct shear and compression-shear conditions, but decreased to 1.20-1.31 under tension-shear loading. Wall-level demand analysis showed that the shear transferred across the vertical joint was significantly affected by both joint location and wall shear span ratio; larger shear span ratios increased the joint shear demand, whereas offset joint layouts reduced the demand. The wall specimens, designed relative to the code-based resistance, exhibited limited joint-related cracking and stable hysteretic behavior, and failed by wall-base flexural damage, indicating the shear-transfer effectiveness of the proposed joint under the tested configurations.

Indexed as

precast concrete shear wallshear resistancesteel-anchor-ring grouted connectionvertical joint

Identifiers

PMID42654578
PMCPMC13514533

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked