Evidence map›Paper›PMID 42649771›Full record

ArticleBioengineering (Basel, Switzerland)2026

Improved SNR and Image Quality of Pediatric MRI with a Shape Conforming High-Density Posterior Cushion Coil.

Terrence Jao, Praveen Jayapal, Jana Vincent, John Pauly, Ceara Stack, Victor Taracila, Fraser Robb, Thomas Grafendorfer, Yun Jeong Stickle, Mark Giancola and 4 more

Abstract read
In one paragraph

Article in Bioengineering (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

14 authors.

Terrence JaoDepartment of Radiology, Stanford University, 300 Pasteur Ave., Stanford, CA 94305, USA.ORCID 0000-0001-6951-1894
Praveen JayapalDepartment of Radiology, Stanford University, 300 Pasteur Ave., Stanford, CA 94305, USA.
Jana VincentGeneral Electric Healthcare, Aurora, OH 44202, USA.ORCID 0000-0002-2707-6000
John PaulyDepartment of Electrical Engineering, Stanford University, Stanford, CA 94305, USA.
Ceara StackGeneral Electric Healthcare, Aurora, OH 44202, USA.
Victor TaracilaGeneral Electric Healthcare, Aurora, OH 44202, USA.
Fraser RobbGeneral Electric Healthcare, Aurora, OH 44202, USA.ORCID 0000-0002-1625-9709
Thomas GrafendorferGeneral Electric Healthcare, Aurora, OH 44202, USA.
Yun Jeong StickleGeneral Electric Healthcare, Aurora, OH 44202, USA.
Mark GiancolaGeneral Electric Healthcare, Aurora, OH 44202, USA.
Clyve Konrad FollanteGeneral Electric Healthcare, Aurora, OH 44202, USA.
Greig ScottDepartment of Electrical Engineering, Stanford University, Stanford, CA 94305, USA.
Shreyas VasanawalaDepartment of Radiology, Stanford University, 300 Pasteur Ave., Stanford, CA 94305, USA.ORCID 0000-0002-1999-6595
Ali B SyedDepartment of Radiology, Stanford University, 300 Pasteur Ave., Stanford, CA 94305, USA.

Funding

Pediatric Cardiopulmonary MRI using RF Navigators and High Dimensional Deep LearningR01HL173035 · NHLBI · UNIVERSITY OF WISCONSIN-MADISON · PI Kevin Michael Johnson, Peder Eric Zufall Larson · 2024 to 2026
$2.1M
Fast and Accurate Cardiovascular MRI with Hyper 4D-FlowR01HL171515 · NHLBI · STANFORD UNIVERSITY · PI Daniel B Ennis, Shreyas S Vasanawala · 2024 to 2026
$1.9M
Rapid and Robust Pediatric MRIR01EB036127 · NIBIB · STANFORD UNIVERSITY · PI Michael Lustig, Shreyas S Vasanawala · 2024 to 2026
$1.8M
NHLBI NIH HHS R01 HL171515NHLBI NIH HHS R01 HL173035NIBIB NIH HHS R01 EB036127
6 · The paper itself

Abstract

A high-density posterior cushion coil (HDPCC) can improve the SNR in pediatric MRI by conforming to the body and minimizing distance to the imaged volume when compared to a conventional rigid built-in table coil array. Posterior coil arrays built into MRI tables are mainstays but provide suboptimal performance in pediatric imaging due to their distance from the imaged volume and lower coil density. Our goal is to improve pediatric MRI by constructing a prototype 30-channel high-density posterior cushion coil (HDPCC) incorporated into a padded cushion. Twenty-five pediatric patients were scanned with the HDPCC, and twenty-five pediatric controls served as the comparison group using standard coils. Two radiologists graded image quality on a 5-point scale. SNR was measured in the right paraspinal musculature and the liver. All images obtained with the HDPCC were diagnostic (mean score 4.13/5). SNR in the superficial tissues of the paraspinal musculature was 34% higher with the HDPCC than with standard coils, while SNR in the deeper tissues of the liver was statistically similar between the two coils. HDPCC yields improved the signal-to-noise ratio in phantoms and pediatric study participants by conforming to the body.

Indexed as

conformal coilhigh density coilimage qualitypediatric abdominal MRIpediatric MRIradiofrequency coil arraysignal-to-noise ratio

Identifiers

PMID42649771
PMCPMC13509388

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.