Evidence map›Paper›PMID 42649629›Full record

ArticleEntropy (Basel, Switzerland)2026

Comprehensive Exergy and Exergoeconomic Analyses and Optimization of a Three-Stage Cascade Refrigeration System Using Environmentally Friendly Refrigerants.

Cenker Aktemur, Ezgi Gurgenc

Abstract read
In one paragraph

Article in Entropy (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Cenker AktemurDepartment of Mechanical Engineering, Faculty of Engineering and Natural Sciences, Sivas University of Science and Technology, 58000 Sivas, Türkiye.ORCID 0000-0001-9045-832X
Ezgi GurgencDepartment of Mechanical Engineering, Faculty of Technology, Firat University, 23119 Elazig, Türkiye.ORCID 0000-0002-0653-4041

Funding

Scientific Research Projects TEKF.26.19
6 · The paper itself

Abstract

Ultra-low-temperature (ULT) refrigeration systems are widely required in applications such as biomedical storage, cryogenic processing, and advanced scientific facilities, where both exergy efficiency and economic performance are critical. In this study, a comprehensive analysis and optimization of the exergy and exergoeconomic performance evaluation of a triple-stage cascade refrigeration system under ULT refrigeration is presented using ethylene (R1150), ethane (R170), propylene (R1270), difluoroethane (R152a), propane (R290), and fluoroethane (R161). A detailed exergy/exergoeconomic analysis, along with an optimization procedure, is performed at both the overall system level and the component-wise level in order to determine the key performance indicators. Minimizing the total cost product rate for each evaporator and condenser temperature is achieved by optimizing the condensing temperatures of the low-temperature cycle and the medium-temperature cycle. The component-wise analysis reveals that major thermodynamic irreversibilities occur in the HTC compressor and throttling valves, with maximum relative exergy destruction reaching 24.71% in TV-3 and the highest exergy destruction ratio reaching 14.92% in the HTC compressor. From an exergoeconomic perspective, the evaporator exhibits the largest combined exergy destruction and capital investment, and operational and maintenance cost rate (up to 24.73 $/h), while the condenser shows the highest exergoeconomic factor (up to 14.24%). The system-level results show that R1150/R170/R152a has the best exergetic and exergoeconomic performance compared to the other refrigeration combinations within the temperature ranges. Compared with R1150/R170/R290, this combination increases exergy efficiency by up to 5.05% for evaporator temperature variations and up to 7.84% for condenser temperature variations while reducing exergy destruction by up to 7.50% and 11.14%, respectively. Furthermore, the same combination decreases the total exergy destruction cost rate and product cost rate by up to 11.15% and 7.88%, respectively. In contrast, R1150/R170/R290 generally exhibits the poorest overall performance. The findings demonstrate that the refrigerant choice is crucial in achieving better exergetic and exergoeconomic performance for ULTs under various evaporator and condenser conditions.

Indexed as

exergoeconomicexergyglobal warming potentialultra-low temperature

Identifiers

PMID42649629
PMCPMC13512805

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.