ArticleBiomimetics (Basel, Switzerland)2026
Anchor-Point Modulation for Multiplanar Hip Torque Generation in Cable-Driven Exosuits: A Geometry-Based Empirical Model.
Article in Biomimetics (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
Abstract
Cable-driven hip exosuits are designed to deliver assistive torques during locomotion. However, most studies focus on assistance in a single plane, even though hip mechanics are inherently multiplanar. This study investigates whether modulation of proximal and distal cable anchor-point locations can systematically alter the distribution of hip assistive torque across anatomical planes. To characterize and estimate three-dimensional torque, we propose a geometric model that incorporates empirically identified correction terms. The model was evaluated using a hip-thigh phantom across 12 anchor configurations and 17 joint-angle conditions, resulting in 204 experimental cases. The results show that anchor-point modulation systematically redistributes assistive torque among the sagittal, frontal, and transverse planes, demonstrating that changes in cable routing can generate distinct multiplanar torque profiles. The model captured major trends and directional characteristics of the torque, with strongest agreement observed for the Mz component, for which the mean absolute percentage error ranged from 4.7% to 10.1%. Estimation errors increased under conditions of greater cable wrap, reflecting the influence of torsion and compliance effects not explicitly represented. These findings establish anchor-point modulation as a practical method for achieving multiplanar hip assistance and provide a foundational empirical baseline for extending cable-driven assistance beyond conventional sagittal-plane operation.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.