Evidence map›Paper›PMID 42645271›Full record

ArticleBiomimetics (Basel, Switzerland)2026

Beyond Design: Ergonomic Numerical Evaluation of a Biomimetic Breast Prosthesis for Daily Use.

Francisco Josué Hernández Rangel, Martha Angélica Cano Figueroa, Jorge Corona Castuera, José Eduardo Monsiváis Rocha, María Cruz Del Rocío Terrones Gurrola, Pedro Cruz Alcantar

Abstract read
In one paragraph

Article in Biomimetics (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Francisco Josué Hernández RangelDoctoral Program in Advanced Manufacturing, CIATEQ A.C., San Luis Potosí Unit, San Luis Potosí C.P. 78395, Mexico.ORCID 0000-0002-8780-556X
Martha Angélica Cano FigueroaCIATEQ A.C., Manzana 5, Lote 1, Distrito de Educación, Salud, Ciencia, Tecnología e Innovación (DESCTI), San Agustín Tlaxiaca C.P. 42162, Mexico.ORCID 0000-0002-2514-8883
Jorge Corona CastueraCIATEQ A.C., Av. Manantiales No. 20, Parque Industrial Bernardo Quintana, El Marqués C.P. 76246, Mexico.ORCID 0000-0002-6598-9847
José Eduardo Monsiváis RochaUnidad Académica Multidisciplinaria Región Altiplano, Universidad Autónoma de San Luis Potosí UASLP-UAMRA, Carretera Cedral km, 5+600, Ejido San José de las Trojes, Matehuala C.P. 78700, Mexico.
María Cruz Del Rocío Terrones GurrolaUnidad Académica Multidisciplinaria Región Altiplano, Universidad Autónoma de San Luis Potosí UASLP-UAMRA, Carretera Cedral km, 5+600, Ejido San José de las Trojes, Matehuala C.P. 78700, Mexico.ORCID 0000-0002-2165-4674
Pedro Cruz AlcantarUnidad Académica Multidisciplinaria Región Altiplano, Universidad Autónoma de San Luis Potosí UASLP-UAMRA, Carretera Cedral km, 5+600, Ejido San José de las Trojes, Matehuala C.P. 78700, Mexico.ORCID 0000-0001-9363-494X

Funding

Secretaría de Ciencia, Humanidades, Tecnología e Innovación
6 · The paper itself

Abstract

External breast prostheses remain the primary noninvasive alternative after mastectomy; however, most commercial designs do not adequately reproduce natural breast biomechanics, heat dissipation, and ventilation behavior during daily activities. This study presents an integrated numerical framework for the ergonomic evaluation of a biomimetic external breast prosthesis under realistic use conditions. A multilayer prosthesis-torso assembly was generated through 3D digitization and modeled using nonlinear hyperelastic finite element formulations. The proposed design incorporated biomimetic lobular internal architecture and microsphere-based posterior ventilation configurations to improve load distribution and heat dissipation. Dynamic behavior was evaluated through modal, harmonic, and spectral analyses, while thermal and airflow simulations were used to assess interface temperature reduction and ventilation efficiency. The results showed physiologically acceptable dynamic displacements, without critical stress concentrations and natural frequencies outside dominant gait excitation ranges. Additionally, biomimetic ventilation configurations reduced contact temperatures by up to 6.58 °C compared with conventional commercial geometries. Overall, the proposed architecture demonstrated mechanical stability, improved thermal performance, ergonomic compatibility, and potential for personalized prosthesis design.

Indexed as

biomimetic designergonomic evaluationexternal breast prosthesisfinite elementheat dissipation

Identifiers

PMID42645271
PMCPMC13510219

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked