Evidence map›Paper›PMID 42645060›Full record

ArticleBiosensors2026

A Blockchain-Enabled Federated Neuro-Symbolic Framework for Secure Wearable Biosensor-Based Health Monitoring.

Khulud Salem Alshudukhi, Noshina Tariq

Abstract read
In one paragraph

Article in Biosensors, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Khulud Salem AlshudukhiDepartment of Computer Science, College of Computer and Information Sciences, Jouf University, Sakaka 72388, Al-Jouf, Saudi Arabia.ORCID 0000-0003-4210-1240
Noshina TariqDepartment of Artificial Intelligence and Data Science, National University of Computer and Emerging Sciences, Islamabad 44000, Pakistan.ORCID 0000-0002-9754-253X

Funding

Jouf University DGSSR-2025-02-01391
6 · The paper itself

Abstract

Wearable biosensors generate continuous physiological data in smart Internet of Disease (IoD) environments. These data can support early disease detection and remote patient monitoring. However, wearable data are often noisy, sensitive, and distributed across different devices. This paper proposes a multimodal neuro-symbolic model to overcome these limitations and incorporates it into a secure Edge-Fog-Cloud framework for anomaly detection in smart healthcare applications. The proposed system integrates the semantic analysis of clinical text using Bio-ClinicalBERT with temporal numerical data using an LSTM-based model, creating a unified neuro-symbolic artificial intelligence (AI) pipeline. Initial data processing is performed at the Edge, whereas inference is carried out at distributed Fog nodes for low-latency anomaly detection. Model training is handled in the Cloud, and privacy-preserving federated learning (FL) is supported through Homomorphic Encryption (HomEnc) to facilitate collaborative model training without sharing raw patient data. A sharded Tangle ledger is also used, with transactions broadcast by the Fog nodes and validated in the Cloud to create tamper-evident transaction logs. Furthermore, Honey Encryption (HoneyEnc) is integrated into the Fog layer to enhance security against brute-force attacks. Experimental results show that the proposed framework achieved 99.22% accuracy and a 99.31% F1-score on the held-out test set, with bootstrap 95% confidence intervals of 98.96-99.47% for accuracy and 99.08-99.53% for the F1-score. It also reduced detection latency from 185 ms in the baseline setting to approximately 50 ms in the Fog-inference setting. The blockchain layer achieved approximately 500 Transactions Per Second (TPS), while higher throughput was observed under increased transaction load and shard parallelism. Because the evaluation is based on synthetic multimodal EHR-like data and controlled simulations, the reported findings should be interpreted as proof-of-concept internal validation rather than evidence of deployment-ready clinical generalizability; external validation using real wearable biosensor data, hospital IoMT streams, or public clinical datasets such as MIMIC-III/MIMIC-IV is required before clinical deployment. These results highlight the potential of the proposed system for secure data processing and trustworthy anomaly detection in smart healthcare environments.

Indexed as

Biosensing TechniquesBlockchainWearable Electronic DevicesComputer SecurityDigital HealthFederated LearningHumansMonitoring, PhysiologicAI in wearable biosensinganomaly detectionBio-ClinicalBERTblockchainfederated learningHomomorphicEncryptionHoney EncryptionIoDneuro-symbolic AIremote patient monitoringsharded tangle ledger

Identifiers

PMID42645060
PMCPMC13511249

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked