Evidence map›Paper›PMID 42645029›Full record

ArticleBiosensors2026

Exceptional-Point-Enhanced Chiral Spoof Localized Surface Plasmon Resonator for Sub-Microliter Glucose Microwave Biosensing.

Zengxiang Wang, Wenfei Mo, Zhaoyang Wang, Cuizhen Sun, Xia Xiao, Xiaojun Huang

Abstract read
In one paragraph

Article in Biosensors, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Zengxiang WangCollege of Communication and Information Engineering, Xi'an University of Science and Technology, Xi'an 710054, China.ORCID 0000-0002-4537-6437
Wenfei MoCollege of Communication and Information Engineering, Xi'an University of Science and Technology, Xi'an 710054, China.
Zhaoyang WangSchool of Microelectronics, State Key Laboratory of Advanced Materials for Intelligent Sensing, Tianjin Key Laboratory of Imaging and Sensing Microelectronic Technology, Tianjin University, Tianjin 300072, China.
Cuizhen SunCollege of Communication and Information Engineering, Xi'an University of Science and Technology, Xi'an 710054, China.
Xia XiaoSchool of Microelectronics, State Key Laboratory of Advanced Materials for Intelligent Sensing, Tianjin Key Laboratory of Imaging and Sensing Microelectronic Technology, Tianjin University, Tianjin 300072, China.
Xiaojun HuangCollege of Communication and Information Engineering, Xi'an University of Science and Technology, Xi'an 710054, China.ORCID 0000-0002-7685-2678

Funding

National Natural Science Foundation of China 62501468, 52574205 and 62471331
6 · The paper itself

Abstract

Microwave resonance sensors are promising for dielectric characterization and biochemical detection. However, their sensing performance is constrained by the relatively long wavelength at microwave frequencies and the limited electromagnetic interaction with small-volume samples. In this paper, an exceptional-point (EP)-enhanced chiral spoof localized surface plasmon (SLSP) resonator is proposed for high sensitivity microwave biosensing with sub-microliter sample volumes. By rotating the chiral resonator relative to the microstrip feeding line, two EPs are obtained at α = 49° and α = 210°. The simulated results show that the EP states generate larger frequency splitting than the reference state under both dielectric-constant variation and detection-limit evaluation, confirming the squareroot response to weak perturbations. Experiments further validate the sensing performance using low-loss dielectric materials and high-loss glucose solutions. For dielectric samples with relative permittivities from 2 to 6.15, the frequency splitting increases from 0.287 GHz to 0.359 GHz. For glucose solutions, the frequency splitting decreases from 1.506 GHz to 1.372 GHz as the glucose amount increases from 2.78 nmol to 27.8 nmol. The proposed sensor requires only about 0.5 μL of sample volume and shows higher sensitivity than reported microwave glucose sensors. These results demonstrate that the EP-enhanced chiral SLSP resonator provides a compact and sensitive platform for trace-volume biochemical detection and integrated microwave biosensing.

Indexed as

Biosensing TechniquesGlucoseMicrowavesSurface Plasmon ResonanceGlucosebiosensordeep subwavelengthexceptional pointsglucose detectionspoof localized surface plasmon (SLSP)

Identifiers

PMID42645029
PMCPMC13511095

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.