Evidence map›Paper›PMID 42645022›Full record

ArticleBiosensors2026

Development of a Quantum Dot-Based Immunochromatographic Assay for Rapid and Sensitive Detection of Non-Medical Etomidate Abuse.

Xin Yan, Liwei Jiang, Xiaolong Zhang, Yizhe Zhao, Zixin Wan, Jun Ma, Chunhui Song, Yikai Wang, Xingliang Liu

Abstract read
In one paragraph

Article in Biosensors, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Xin YanBeijing Key Laboratory of Psychoactive Substances Detection and Control, Beijing Narcotics Control Technology Center, Beijing 100164, China.
Liwei JiangBeijing Key Laboratory of Psychoactive Substances Detection and Control, Beijing Narcotics Control Technology Center, Beijing 100164, China.
Xiaolong ZhangScience and Technology Research Center of China Customs, Beijing 100026, China.
Yizhe ZhaoBeijing Key Laboratory of Psychoactive Substances Detection and Control, Beijing Narcotics Control Technology Center, Beijing 100164, China.
Zixin WanBeijing Key Laboratory of Psychoactive Substances Detection and Control, Beijing Narcotics Control Technology Center, Beijing 100164, China.
Jun MaBeijing Key Laboratory of Psychoactive Substances Detection and Control, Beijing Narcotics Control Technology Center, Beijing 100164, China.
Chunhui SongBeijing Key Laboratory of Psychoactive Substances Detection and Control, Beijing Narcotics Control Technology Center, Beijing 100164, China.
Yikai WangScience and Technology Research Center of China Customs, Beijing 100026, China.
Xingliang LiuBeijing Key Laboratory of Psychoactive Substances Detection and Control, Beijing Narcotics Control Technology Center, Beijing 100164, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Etomidate is an ultrashort-acting imidazole-derived intravenous anesthetic. The non-medical abuse of etomidate as a new psychoactive substance has emerged as a critical public health challenge globally, particularly among adolescents, necessitating sensitive, rapid detection methods for forensic analysis. This study developed a quantum dot-based immunochromatographic test strip and a corresponding rapid detection method for the sensitive detection of etomidate acid in urine. CdSe/ZnS fluorescent quantum dot microspheres were used as labeling probes combined with specific monoclonal antibodies, and the detection protocol utilized a portable fluorescence reader. The method's validation demonstrated a linear range of 10-2000 ng/mL (y = -0.231lnx + 0.5241, r = -0.991), with intra-batch and inter-batch coefficients of variation below 12%. The spike recovery rates ranged from 88.24% to 95.69%. Cross-reactivity testing against 12 common drugs and structural analogs showed no interference. The detection limit of 10 ng/mL represents a substantial improvement over conventional colloidal gold strips and approaches LC-MS/MS sensitivity. Assays of real urine specimens confirmed that the immunochromatographic test strip and detection method possess favorable accuracy and reliability. This fluorescent quantum dot-based immunochromatographic assay provides rapid, quantitative, and highly specific etomidate screening suitable for on-site forensic applications, effectively bridging front-end rapid testing with confirmatory laboratory analysis.

Indexed as

EtomidateQuantum DotsSubstance Abuse DetectionChromatography, AffinityHumansImmunoassayLimit of DetectionEtomidateetomidatefluorescent quantum dot microspheresimmunochromatographic test striprapid detection

Identifiers

PMID42645022
PMCPMC13510451

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.