Evidence map›Paper›PMID 42643949›Full record

ArticleClinical ophthalmology (Auckland, N.Z.)2026

Optical Biometry Errors in Eyes with Iris-Claw Phakic Intraocular Lenses.

Wei-Lun Huang, Shao-Wei Huang, Ya-Ting Chiu, Huai-Wen Chang, Hsiao-Ling Shen, Wei-Jen Huang, Fung-Rong Hu

Abstract read
In one paragraph

Article in Clinical ophthalmology (Auckland, N.Z.), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Wei-Lun Huang *Department of Ophthalmology, National Taiwan University Hospital Hsinchu Branch, Hsinchu, Taiwan.ORCID 0000-0002-5503-9418
Shao-Wei Huang *Department of Education, National Taiwan University Hospital, College of Medicine, National Taiwan University, Taipei, Taiwan.
Ya-Ting ChiuDepartment of Ophthalmology, National Taiwan University Hospital, College of Medicine, National Taiwan University, Taipei, Taiwan.
Huai-Wen ChangDepartment of Ophthalmology, National Taiwan University Hospital, College of Medicine, National Taiwan University, Taipei, Taiwan.
Hsiao-Ling ShenDepartment of Ophthalmology, National Taiwan University Hospital, College of Medicine, National Taiwan University, Taipei, Taiwan.
Wei-Jen HuangDepartment of Ophthalmology, Ray Guard Eye Center, Taipei, Taiwan.
Fung-Rong HuDepartment of Ophthalmology, National Taiwan University Hospital, College of Medicine, National Taiwan University, Taipei, Taiwan.ORCID 0000-0002-2102-5317

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: To evaluate the effect of iris-claw phakic intraocular lenses (pIOLs) on anterior chamber depth (ACD) measurement by optical biometers and the potential impact of ACD errors on hypothetical intraocular lens (IOL) power selection for cataract surgery. Patients and Methods: Seventy-six eyes of 38 patients with iris-claw pIOLs (Artiflex) underwent biometry using Pentacam (Scheimpflug), Lenstar LS-900 (optical low-coherence reflectometry), and Eyestar 900 (swept-source OCT). The failure and misidentification rates of ACD measurement were recorded. Eyestar B-scans were manually reviewed and corrected when segmentation errors were identified. Hypothetical IOL power was calculated using Barrett Universal II and SRK/T formulas. Results: Pentacam successfully measured ACD in all 76 eyes. Lenstar LS-900 angd Eyestar 900 failed to provide ACD measurements in 4 eyes (5.3%) and 14 eyes (18.4%), respectively. Using a predefined threshold of >10% deviation from the Pentacam value, inaccurate ACD measurements were identified in 30 eyes (39.5%) with Lenstar and in 17 eyes (22.4%) with Eyestar. On Eyestar, 20 eyes (26.3%) showed misidentification of the anterior pIOL surface as the anterior capsule of the crystalline lens, and 11 eyes (14.5%) were interpreted as aphakic. After manual correction, Eyestar ACD values closely matched Pentacam measurements, with a mean difference of 0.04 ± 0.03 mm. Correction of erroneous ACD measurements changed Barrett Universal II-based hypothetical IOL power selection by at least 0.50 D in 7 of 17 affected eyes (41.2%). Conclusion: In eyes with iris-claw pIOLs, automated optical biometers may misidentify ocular structures and underestimate ACD, potentially leading to clinically meaningful differences in hypothetical IOL power selection. Manual review and correction of Eyestar B-scan images restored ACD measurements to close agreement with Pentacam values. These findings highlight the importance of careful inspection of raw biometry images in such eyes, particularly when using formulas that incorporate measured ACD.

Indexed as

anterior chamber depthintraocular lens power calculationiris-claw phakic intraocular lensoptical biometrysegmentation errorswept-source optical coherence tomography

Identifiers

PMID42643949
PMCPMC13505771

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.