ArticlePloS one2026
Temperature characteristics of fiber-optic shearer cables.
Article in PloS one, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
12 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
During the reciprocating motion of a coal shearer, shearer cables are exposed to complex underground conditions, including high load current, repeated bending and dragging, and limited heat dissipation. These factors may lead to excessive conductor temperature and pose safety risks. However, the temperature response of embedded optical-fiber units in shearer cables under different motion states remains insufficiently clarified, especially the relationship between optical-fiber temperature and the temperatures of key cable components. To address this gap, an MCPT-1.9/3.3(3 × 120 + 1 × 70 + 4 × 10) shearer cable was taken as the engineering object, and three optical-fiber unit structures were designed and embedded to form three fiber-optic shearer cable configurations. Parametric models were developed using Rhino-Grasshopper, and COMSOL Multiphysics was used to analyze the effects of cable structure, load current, and ambient temperature under straight-line and bending motions. The results show that the maximum optical-fiber temperatures of the three structures are 57.8°C, 58.1°C, and 63.8°C under straight-line motion, increasing to 69.5°C, 70.1°C, and 77.4°C under bending motion. Optical-fiber temperature rises with increasing load current and ambient temperature. Least-squares fitting further establishes relationships between optical-fiber temperature and the temperatures of the power conductor, control conductor, polyimide buffer layer, and outer sheath. The main contribution of this study is to provide a quantitative basis for temperature monitoring and structural optimization of fiber-optic shearer cables under different operating conditions.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.