ArticleRadiological physics and technology2026

Comparison of breast-level surface dose between single-energy CT and fast kilovoltage-switching dual-energy CT under matched CTDIvol conditions: a chest phantom study.

Mako Yamada, Takanori Masuda, Norimi Nishiyama, Junichi Nakagawa, Nanami Usui, Hitoshi Takahata, Takashi Amano, Shinichi Arao, Takeshi Nakaura

Abstract read
PubMed Publisher
In one paragraph

Article in Radiological physics and technology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Mako YamadaDepartment of Radiological Technology, Tsuyama Chuo Hospital, Okayama, Japan.
Takanori MasudaDepartment of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, 288 Matsushima, Kurashiki-City, Okayama, 701-0193, Japan. takanorimasuda@yahoo.co.jp.ORCID http://orcid.org/0000-0002-4164-4369
Norimi NishiyamaDepartment of Radiological Technology, Okayama Saiseikai General Hospital, Okayama, Japan.
Junichi NakagawaDepartment of Radiological Technology, Okayama Saiseikai General Hospital, Okayama, Japan.
Nanami UsuiDepartment of Radiological Technology, Okayama Saiseikai General Hospital, Okayama, Japan.
Hitoshi TakahataDepartment of Radiological Technology, National Cerebral and Cardiovascular Center Hospital, Osaka, Japan.
Takashi AmanoDepartment of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, 288 Matsushima, Kurashiki-City, Okayama, 701-0193, Japan.
Shinichi AraoDepartment of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, 288 Matsushima, Kurashiki-City, Okayama, 701-0193, Japan.
Takeshi NakauraDepartment of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University, 1-1-1 Honjo, Kumamoto, 860-8556, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This phantom study compared breast-level surface dose and image noise between single-energy CT (SECT) and fast kilovoltage-switching dual-energy CT (DECT) under matched volume CT dose index (CTDIvol) conditions. A chest phantom was scanned using a 256-row CT scanner. Surface dose was measured with real-time dosimeters placed on the bilateral anterior chest wall at the breast level and corresponding bilateral posterior positions. Tube currents of 195 mA for SECT and 250 mA for DECT provided matched console-displayed CTDIvol values. Each protocol was repeated 20 times as technical replicates. Image noise was measured in five circular regions of interest at the bilateral anterior and posterior chest walls and heart. Mean surface dose was lower with DECT than SECT at the breast level (15.86 vs. 17.02 mGy; mean difference [DECT minus SECT], -1.16 mGy; 95% confidence interval [CI], -1.71 to -0.61; P < 0.001) and posterior surface (15.77 vs. 17.26 mGy; mean difference, -1.49 mGy; 95% CI, -2.21 to -0.77; P < 0.001). Mean image noise was 7.08 HU with DECT and 6.66 HU with SECT, with no statistically significant difference (mean difference, 0.42 HU; 95% CI, -0.17 to 1.01; P = 0.160). Under the tested conditions, DECT showed lower anterior and posterior surface doses than SECT performed without CT automatic exposure control. No statistically significant difference in image noise was observed, but this does not establish equivalent image quality. These findings should not be generalized to clinically optimized SECT protocols.

Indexed as

Breast-level surface doseChest CTDual-energy CTPhantom studySingle-energy CT