SynthesisFrontiers in surgery2026
Efficacy and safety of flow diverters for the treatment of intracranial aneurysms: a systematic review and meta-analysis.
Synthesis in Frontiers in surgery, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
13 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Objective: To examine the efficacy and safety of multiple brands of flow diverters (FDs) in the treatment of intracranial aneurysms (IAs). Methods: PubMed, EMBASE, and Cochrane were searched for studies on FDs treatment of IAs published until April 11, 2023. The efficacy outcomes were procedural success rate, retreatment, and complete/near-complete occlusion rate. The safety outcomes were postoperative in-stent restenosis (ISR), IA rupture, mortality, cerebrovascular events, and neurogenic death. Results: 104 studies were included. The pooled procedural success rate was 99% (95% CI: 98%-99%). The pooled overall and 1-year retreatment rates were 4% (95% CI: 3%-5%) and 1% (95% CI: 0%-3%), respectively. The pooled complete occlusion and complete/near-complete occlusion rates were 73% and 85% at 6 months, and 80% and 87% at 12 months, respectively. Subgroup analyses suggested p64™ had high 6-month (79%, 95% CI: 72%-84%) and 12 months (91%, 95% CI: 82%-97%) complete occlusion rates and low rescue rates (2%, 95% CI: 0%-6%). The overall aneurysm rupture rate, all-cause mortality, and overall ISR were 1%, 2% and 5%, respectively. The 1-month rates of neurogenic death, hemorrhagic, ischemic, and thromboembolic events were 1%, 2%, 5% and 3%, respectively. Conclusion: FDs treatment for IA achieves high procedural success and occlusion rates, and the safety profile is favorable with a low incidence of IA rupture and mortality. However, these findings should be interpreted with caution due to the substantial clinical heterogeneity and the predominance of observational single-arm studies among the included literature.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.