ArticleJournal of applied clinical medical physics2026
Clinical evaluation of novel deep learning-based auto-segmentation software: Utility and potential pitfalls.
Article in Journal of applied clinical medical physics, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
11 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundAccurate contouring of target volumes and organs at risk is critical in radiotherapy. While deep learning (DL) models offer automated contouring, their clinical applicability to real-world cases containing anatomical variations and artifacts requires rigorous validation. PURPOSE: To evaluate the clinical accuracy and potential vulnerabilities of RatoGuide, novel DL-based auto-segmentation software, using a dataset including atypical cases derived from routine clinical practice.
methodsThis single-center retrospective study included 69 thoracic and male pelvic cases. The cohort was intentionally selected to encompass diverse anatomies and artifacts (e.g., pacemakers, SpaceOAR implants, artificial femoral head replacements, and unilateral atelectasis). Auto-contours generated by RatoGuide were compared with expert-approved manual contours. Performance was evaluated quantitatively using the Dice Similarity Coefficient (DSC) and 95th percentile Hausdorff Distance (HD95), and qualitatively via a 5-point visual assessment scale by four independent reviewers. Statistical comparisons between cohorts were performed using the Mann-Whitney U test. Additionally, a dosimetric evaluation was conducted for male pelvic cases to assess clinical impact.
resultsIn typical cases, the software maintained high segmentation accuracy (thorax: mean DSC 0.856, mean HD95 6.89 mm; male pelvis: mean DSC 0.874, mean HD95 4.11 mm). However, performance declined in atypical cohorts (thorax: mean DSC 0.808, p = 0.0457, mean HD95 12.22 mm, p = 0.0002; male pelvis: mean DSC 0.828, p = 0.1620, mean HD95 6.16 mm, p = 0.0075). Notable decreases in accuracy were observed in challenging scenarios, such as artificial femoral head replacements (DSC: 0.754) and unilateral atelectasis (DSC: 0.784). Qualitative assessment revealed that errors were primarily due to anatomical factors and artifacts. Furthermore, the dosimetric evaluation identified one critical false-negative error where a dose constraint violation was overlooked when the DL contour was used.
conclusionsRatoGuide demonstrated favorable performance in typical cases, but accuracy declined in atypical cases with artifacts or altered anatomy. For clinical implementation, rigorous visual verification and manual review by experts are essential, particularly for atypical cases and organs in high-dose gradient regions.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.