Evidence map›Paper›PMID 42638441›Full record

ArticleJournal of applied clinical medical physics2026

Dosimetric and radiobiological evaluations as well as technical aspects of left breast treatment employing DIBH with SGRT in radiotherapy with IMRT step and shoot, IMRT Dynamic MLC and VMAT.

Julien Rolland, Stéphane Payan, Pierre Fau, Hugues Mailleux, Agnès Tallet

Abstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Julien RollandDepartment of Medical Physics, Centre Hospitalier InterCommunal des Alpes du Sud, Gap, France.
Stéphane PayanDepartment of Medical Physics, Centre Hospitalier InterCommunal des Alpes du Sud, Gap, France.
Pierre FauDepartment of Medical Physics, Institut Paoli Calmettes, Marseille, France.
Hugues MailleuxDepartment of Medical Physics, Institut Paoli Calmettes, Marseille, France.
Agnès TalletDepartment of Radiotherapy, Institut Paoli Calmettes, Marseille, France.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundTreatment of the left breast using deep inspiration breath hold (DIBH), combined with surface guided radiotherapy (SGRT), has emerged as the standard for reducing the dose to the heart, the left anterior descending coronary artery (LAD), and the ipsilateral lung. Since this treatment is administered during breath hold (BH) phases, it is beneficial to limit the duration of delivery to improve patient comfort. Furthermore, the SGRT signal can be disrupted when the gantry passes in front of the left SGRT camera during the delivery with volumetric modulated arc therapy (VMAT), which complicates the treatment process. In contrast, using a simpler treatment plan with two tangential beams with intensity modulated radiation therapy (IMRT) helps avoid this difficulty. For image guided radiotherapy (IGRT) as well, monitoring becomes more complex with the addition of the imaging panel and the X-ray tube for the SGRT signal. PURPOSE: This study compares dosimetric and radiobiological differences between two methods in IMRT step and shoot (SS-IMRT) or dynamic multileaf collimator (DMLC-IMRT) using two tangential beams and VMAT with two arcs.

methodsTwenty left breasts were planned using SS-IMRT, DMLC-IMRT and VMAT. The comparison is based on dosimetric criteria at target (D

resultsThe results are listed for SS-IMRT, DMLC-IMRT and VMAT, respectively. For the PTV: D95% 37.5 Gy, 38.3 Gy, 38.4 Gy (p < 0.05 DMLC-IMRT & VMAT vs SS-IMRT); CI 0.74, 0.76, 0.83 (p < 0.05); HI 0.15, 0.11, 0.11 (p > 0.05). TCP: 91.2%, 92.2% and 92.9% (p < 0.05). For OARs; heart: D

conclusionsIn most cases, choosing DMLC-IMRT will result in a plan similar to VMAT and superior to SS-IMRT. Compared to SS-IMRT, DMLC-IMRT delivers a slightly higher dose to contralateral OARs, with a slight increase in the risk of radiation-induced cancer, but lower than VMAT. The main advantage is that it eliminates camera occlusion issues, which can lead to erroneous SGRT signals during treatment and IGRT verification. DMLC-IMRT reduces treatment time by an average of 42% compared to VMAT, which will remain the solution for the most complex morphologies.

Indexed as

Breast NeoplasmsBreath HoldingOrgans at RiskRadiotherapy, Image-GuidedRadiotherapy, Intensity-ModulatedRadiotherapy Planning, Computer-AssistedUnilateral Breast NeoplasmsFemaleHumansRadiometryRadiotherapy DosageDIBHDMLC‐IMRTIMRTleft breastNTCPSCCPSGRTSS‐IMRTTCPVMAT

Identifiers

PMID42638441
PMCPMC13504233

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.