Evidence map›Paper›PMID 42635838›Full record

ArticleJournal of molecular modeling2026

A novel "turn-on" fluorescence probe for chromium(III) sensing: experimental validation and theoretical insights.

Sreedev G Nair, Harikrishna Nair, J K Kiran Kumar, Brahma Teja, P Shiva Kumar, C N Sundaresan, A Sunil

Abstract read
PubMed Publisher
In one paragraph

Article in Journal of molecular modeling, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Sreedev G NairDepartment of Chemistry, Sri Sathya Sai Institute of Higher Learning (Deemed to be University), Prasanthi Nilayam, Sri Sathya Sai District, Puttaparthi, 515134, Andhra Pradesh, India.ORCID http://orcid.org/0009-0002-2948-4371
Harikrishna NairDepartment of Chemistry, Sri Sathya Sai Institute of Higher Learning (Deemed to be University), Prasanthi Nilayam, Sri Sathya Sai District, Puttaparthi, 515134, Andhra Pradesh, India.ORCID http://orcid.org/0009-0007-2691-5355
J K Kiran KumarDepartment of Chemistry, Sri Sathya Sai Institute of Higher Learning (Deemed to be University), Prasanthi Nilayam, Sri Sathya Sai District, Puttaparthi, 515134, Andhra Pradesh, India.ORCID http://orcid.org/0000-0002-0781-8978
Brahma TejaDepartment of Chemistry, Sri Sathya Sai Institute of Higher Learning (Deemed to be University), Prasanthi Nilayam, Sri Sathya Sai District, Puttaparthi, 515134, Andhra Pradesh, India.
P Shiva KumarDepartment of Chemistry, Sri Sathya Sai Institute of Higher Learning (Deemed to be University), Prasanthi Nilayam, Sri Sathya Sai District, Puttaparthi, 515134, Andhra Pradesh, India.
C N SundaresanDepartment of Chemistry, Sri Sathya Sai Institute of Higher Learning (Deemed to be University), Prasanthi Nilayam, Sri Sathya Sai District, Puttaparthi, 515134, Andhra Pradesh, India.ORCID http://orcid.org/0000-0001-7327-684X
A SunilDepartment of Chemistry, Sri Sathya Sai Institute of Higher Learning (Deemed to be University), Prasanthi Nilayam, Sri Sathya Sai District, Puttaparthi, 515134, Andhra Pradesh, India. asunil@sssihl.edu.in.ORCID https://orcid.org/0000-0003-4747-5567

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

contextTrivalent chromium exhibits a dual nature. It acts as a necessary micronutrient for lipid and carbohydrate metabolism at low levels in the body, but causes dangerous genotoxic harm at higher thresholds. Hence, precise tracking of trace trivalent chromium is absolutely essential. Compounding this, its intracellular detection remains highly obstructed by paramagnetic fluorescence quenching and a deficiency in selective probes. Addressing this material and analytical challenge, this work reports the development of an ultrasensitive "turn-on" fluorogenic chemosensor utilizing a novel azo-based dye, 2-[(E)-(4-methylphenyl)diazenyl]phenol (MPDP). Unlike traditional methods restricted to microgram boundaries, this newly developed strategy establishes a wide dynamic linearity descending to an extraordinary femtogram detection limit. The probe operates via a chelation-enhanced fluorescence (CHEF) pathway at pH 9.0, successfully validating chromium(III) quantification in plant matrices. Furthermore, integration of density functional theory (DFT) and non-covalent interaction (NCI) analysis successfully maps out the precise, thermodynamically favored octahedral coordination mechanics driving its extreme metal selectivity.

methodsAll the geometry optimizations of the 2-[(E)-(4-methylphenyl)diazenyl]phenol (MPDP) monomer, its corresponding isomers, and resultant chromium(III) complexes were performed utilizing density functional theory (DFT). Calculations were executed at the M06-2X level of theory, implemented within the Gaussian 16 software package. The standard 6-311++G(d,p) all-electron basis set was assigned for light atoms (C, H, N, O, Cl), paired with Los Alamos LANL2DZ effective core potentials (ECP) to accurately describe the core and valence electrons of the heavy chromium center. Vibrational frequency analyses were systematically conducted following geometry optimization to guarantee that all structures corresponded to true potential energy surface minima, verified by the total absence of imaginary frequencies. Thermodynamic properties and Basis Set Superposition Error (BSSE)-corrected binding energies were evaluated using the counterpoise method. To map out real-space weak interactions, non-covalent interaction (NCI) analysis and reduced density gradient (RDG) isosurface were visualized using Multiwfn and Visual Molecular Dynamics (VMD) software.

Indexed as

CHEFChromium (III)DFTMPDPNCIRDGSensing

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.