Evidence map›Paper›PMID 42634753›Full record

ArticleCureus2026

Efficacy and Safety of Percutaneous Pedicle Screw Fixation for Neurologically Intact Thoracolumbar Burst Fractures: A Prospective Interventional Study.

Deepak K Saini, Krishna Kumar, Gnanaprakash Gurusamy, Ijack Debbarma, Ashish Jaiman, Tankeshwar Boruah

Abstract read
In one paragraph

Article in Cureus, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Deepak K SainiOrthopedics, Maharishi Chyawan Government Medical College and Rao Tula Ram Hospital, Narnaul, IND.
Krishna KumarOrthopedics, Vardhman Mahavir Medical College and Safdarjung Hospital, New Delhi, IND.
Gnanaprakash GurusamySpine Surgery, Ganga Medical Centre and Hospitals Private Limited, Coimbatore, IND.
Ijack DebbarmaOrthopedics, Agartala Government Medical College (AGMC) and Govind Ballabh Pant (GBP) Hospital, Agartala, IND.
Ashish JaimanOrthopedics, Vardhman Mahavir Medical College and Safdarjung Hospital, New Delhi, IND.
Tankeshwar BoruahOrthopedics, Vardhman Mahavir Medical College and Safdarjung Hospital, New Delhi, IND.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundOpen posterior short-segment pedicle instrumentation is an established treatment for unstable thoracolumbar fractures but carries approach-related morbidity from paraspinal muscle stripping. Percutaneous pedicle screw fixation (PPSF) aims to provide comparable stabilization with reduced soft-tissue trauma. We evaluated the perioperative profile, radiographic correction, and screw-placement accuracy of PPSF performed under single conventional fluoroscopy in neurologically intact patients.

methodsIn this prospective, single-arm interventional study, 46 consecutive patients aged 18-50 years with AO Spine type A3/A4 thoracolumbar fractures and intact neurology (American Spinal Injury Association (ASIA) grade E) underwent short-segment PPSF over an 18-month period at a tertiary public hospital. Operative time, intraoperative blood loss, visual analog scale (VAS) pain score, length of hospital stay, sagittal Cobb angle, and anterior vertebral body height (AVBH) were recorded. Screw placement was graded on postoperative CT using the Gertzbein-Robbins classification. Preoperative and postoperative radiographic parameters were compared using paired analysis.

resultsMean age was 30.8±8.8 years; 28 patients (60.9%) were female. The most common mechanism of injury was a fall from height (65.2%), and the most commonly affected level was L2 (54.3%). Mean operative time was 108.2±12.1 minutes, and mean blood loss was 102.6±16.1 mL. Mean length of hospital stay was 2.6±0.7 days, and mean VAS score decreased from 4.4±0.6 (day 0) to 2.6±0.7 (day 3). Cobb angle improved from 18.9±5.9° to 8.7±5.9°, and AVBH improved from 55.3±11.0% to 74.3±10.4% (both p<0.01). Of 184 screws, 173 (94.0%) were Gertzbein-Robbins grade A, whereas 11 (6.0%) were malpositioned (grades B-D), with none causing neurovascular injury. There were no infections, implant failures, or screw revisions.

conclusionPPSF is a safe and minimally invasive technique that demonstrated favorable immediate perioperative and radiographic outcomes, with high pedicle screw placement accuracy and no early procedure-related complications in selected neurologically intact patients with thoracolumbar fractures. Further prospective comparative studies with longer follow-up are required to establish its long-term clinical outcomes and comparative effectiveness.

Indexed as

burst fracturefluoroscopygertzbein-robbinsminimally invasive spine surgerypercutaneous pedicle screw fixationthoracolumbar fracture

Identifiers

PMID42634753
PMCPMC13499931

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.