Evidence map›Paper›PMID 42634676›Full record

ArticlePatient preference and adherence2026

A Baseline Prediction Model for First-Year CPAP Treatment Disengagement in Adults with Obstructive Sleep Apnea: A Secondary Analysis of a Danish Cohort.

Hongbing Yu, Yonghao Wei, Shufen Li, Dan Liu

Abstract read
In one paragraph

Article in Patient preference and adherence, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Hongbing YuDepartment of Otorhinolaryngology, Head and Neck Surgery, Affiliated Hospital of Jiujiang University, Jiujiang, Jiangxi, 332000, People's Republic of China.
Yonghao WeiDepartment of Otorhinolaryngology, Head and Neck Surgery, Affiliated Hospital of Jiujiang University, Jiujiang, Jiangxi, 332000, People's Republic of China.
Shufen LiDepartment of Otolaryngology, Head and Neck Surgery, The First Affiliated Hospital, Jiangxi Medical College, Nanchang University, Nanchang, 330006, People's Republic of China.
Dan LiuDepartment of Otorhinolaryngology, Head and Neck Surgery, Affiliated Hospital of Jiujiang University, Jiujiang, Jiangxi, 332000, People's Republic of China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: To estimate and internally evaluate a fixed baseline model for recorded first-year continuous positive airway pressure (CPAP) treatment disengagement before device-use data are available and compare it with more complex alternatives. Patients and Methods: We conducted a secondary analysis of a Danish single-center cohort that initiated CPAP in 2012-2013. The outcome was the recorded 52-week treatment-status event, which did not distinguish active discontinuation from loss to follow-up. Of 695 participants, 662 had determinate status and 94 events. The fixed logistic model included current smoking, Epworth Sleepiness Scale (ESS) score, and apnea-hypopnea index (AHI), with coefficients estimated in 632 complete cases (85 events). Performance was evaluated by repeated 10-fold cross-validation with bootstrap confidence intervals (CIs). Results: Current smoking was associated with higher odds of the recorded outcome (odds ratio [OR] 2.45, 95% CI 1.47-4.07). Higher ESS (OR per 5-point increase, 0.68; 95% CI, 0.53-0.87) and AHI (OR per 10 events/hour increase, 0.56; 95% CI, 0.45-0.68) were associated with lower odds. The cross-validated area under the curve was 0.762 (95% CI, 0.709-0.812), the Brier score was 0.103 (0.087-0.119), the calibration intercept was -0.001 (-0.259 to 0.226), and the calibration slope was 0.927 (0.624-1.298). In 662 participants, extended and full models did not consistently improve prediction error. The 94 events could not be separated into active discontinuation and loss to follow-up. Conclusion: Three routinely available baseline measures provided moderate predictive information, while broader and penalized models offered no consistent improvement. These findings provide a fixed-horizon benchmark for external validation in contemporary CPAP cohorts that directly assess device use, treatment preferences, and treatment burden.

Indexed as

continuous positive airway pressureinternal validationobstructive sleep apneaprediction modeltreatment disengagement

Identifiers

PMID42634676
PMCPMC13500004

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.