The Accuracy of Noise Measurements in Patient CT Images.

Francesco Ria, Martina Talarico, Em Harkness, Ehsan Abadi, Ehsan Samei

Abstract read
In one paragraph

Article in Academic radiology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Francesco RiaCarl E. Ravin Advanced Imaging Labs, Clinical Imaging Physics Group, Center for Virtual Imaging Trials, Departments of Radiology, Duke University Health System, Durham, NC, USA (F.R., E.S.). Electronic address: francesco.ria@duke.edu.
Martina TalaricoCarl E. Ravin Advanced Imaging Labs, Center for Virtual Imaging Trials, Departments of Radiology, Duke University Health System, Durham, NC, USA (M.T., E.H., E.A.); Department of Medical Physics, SABES-ASDAA Bolzano Hospital, Bolzano, Italy (M.T.). Electronic address: martina.talarico@duke.edu.
Em HarknessCarl E. Ravin Advanced Imaging Labs, Center for Virtual Imaging Trials, Departments of Radiology, Duke University Health System, Durham, NC, USA (M.T., E.H., E.A.). Electronic address: emily.harkness@duke.edu.
Ehsan AbadiCarl E. Ravin Advanced Imaging Labs, Center for Virtual Imaging Trials, Departments of Radiology, Duke University Health System, Durham, NC, USA (M.T., E.H., E.A.). Electronic address: ehsan.abadi@duke.edu.
Ehsan SameiCarl E. Ravin Advanced Imaging Labs, Clinical Imaging Physics Group, Center for Virtual Imaging Trials, Departments of Radiology, Duke University Health System, Durham, NC, USA (F.R., E.S.). Electronic address: ehsan.samei@duke.edu.

Funding

TR&D Project 3: Virtual ReadersP41EB028744 · NIBIB · DUKE UNIVERSITY · PI Ehsan Samei · 2021 to 2026
$7.8M
Accuracy and Precision in CT Quantification of COPD Through Virtual Imaging TrialsR01HL155293 · NHLBI · DUKE UNIVERSITY · PI ABADI, EHSAN · 2021 to 2025
$2.2M
Quality and Safety Monitoring of Clinical Computed Tomography PracticeR44EB031658 · NIBIB · METIS HEALTH ANALYTICS, LLC · PI SAPP, ARMISTEAD WRIGHT · 2021 to 2023
$1.9M
NHLBI NIH HHS R01 HL155293NIBIB NIH HHS P41 EB028744NIBIB NIH HHS R44 EB031658
6 · The paper itself

Abstract

RATIONALE AND

objectiveNoise magnitude is one of the image quality indicators in computed tomography (CT) for assessing imaging performance, and the CMS (Centers for Medical and Medicaid Services) recently included a measure of noise magnitude in terms of "global noise". Despite its importance, no standard method currently exists to measure noise magnitude in patient images. Theoretically, the most accurate approach is to assess voxel value variation across repeated images, the so-called ensemble noise. Obviously, such a method is not ethically feasible in actual patients. To surmount this impasse, we deployed virtual imaging techniques to benchmark three noise magnitude calculation methods against two gold standard ensemble noise measures across 36 imaging conditions. MATERIALS AND

methodsOver 1800 virtual image datasets were generated from imaging an American College of Radiology (ACR) phantom and Extended Cardiac-Torso (XCAT) human models using a validated, scanner-specific CT simulator (DukeSim). The ACR phantom was imaged under 36 different imaging conditions defined by combinations of chest and abdominopelvic protocols, three dose levels, three reconstruction kernels, and both Filtered Back Projection and Iterative Reconstruction algorithms. Under the same conditions, XCAT models were repeatedly imaged 50 times. Noise magnitudes in the ACR phantom were calculated in 5 circular regions of interest. In patients, noise was measured in the air surrounding the body and in soft tissues by applying HU < -900 and -300 ≤ HU ≤ 100 thresholds, respectively. For each imaging condition, measured noise magnitudes were compared against the ensemble noise in soft tissue, liver, and lungs.

resultsAcross all imaging conditions, noise measurements in the ACR phantom and in the air surrounding the patient underestimated ensemble noise by approximately 60% and 50%, respectively. In contrast, soft tissue-based noise measurements were closer to the gold standard with median differences between -8% and +4%.

conclusionThis study introduced a virtual imaging-based framework to benchmark clinical CT noise metrics against ensemble noise measures. Virtual imaging enabled objective comparison of different noise magnitude calculation methods in large, realistic populations simulating clinical conditions. Noise measured in the air cannot represent soft tissue noise. The results validated soft tissue-based noise measurements as a reliable surrogate to inform protocol design, technology assessment, and equitable healthcare reimbursement.