Article in NEJM AI, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
2 · The registry
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
B WiestlerSchool of Medicine and Health, TUM University Hospital, Technical University of Munich, Munich, Germany.ORCID 0000-0002-2963-7772
J S KirschkeSchool of Medicine and Health, TUM University Hospital, Technical University of Munich, Munich, Germany.ORCID 0000-0002-7557-0003
E O RiedelSchool of Medicine and Health, TUM University Hospital, Technical University of Munich, Munich, Germany.ORCID 0000-0003-2259-9221
R WiestDepartment of Diagnostic and Interventional Neuroradiology, University Hospital Berne and University of Bern, Bern, Switzerland.ORCID 0000-0001-7030-2045
C YalcinResearch Institute of Computer Vision and Robotics, University of Girona, Girona, Spain.ORCID 0009-0009-0032-3612
R E HamadacheResearch Institute of Computer Vision and Robotics, University of Girona, Girona, Spain.ORCID 0009-0000-0214-9165
C LisazoResearch Institute of Computer Vision and Robotics, University of Girona, Girona, Spain.ORCID 0009-0004-2364-9520
J SalviResearch Institute of Computer Vision and Robotics, University of Girona, Girona, Spain.ORCID 0000-0002-9482-7126
A CasamitjanaResearch Institute of Computer Vision and Robotics, University of Girona, Girona, Spain.ORCID 0000-0002-0539-3638
X LladóResearch Institute of Computer Vision and Robotics, University of Girona, Girona, Spain.ORCID 0000-0003-2777-3479
U M L-T EstradaResearch Institute of Computer Vision and Robotics, University of Girona, Girona, Spain.ORCID 0009-0006-8747-2036
V AbramovaResearch Institute of Computer Vision and Robotics, University of Girona, Girona, Spain.ORCID 0000-0001-5425-6800
L GiancardoCenter for Precision Health, McWilliams School of Biomedical Informatics, University of Texas Health Science Center at Houston, Houston, USA.ORCID 0000-0002-4862-2277
A OliverResearch Institute of Computer Vision and Robotics, University of Girona, Girona, Spain.ORCID 0000-0002-0115-0647
P CasademuntPhysense, BCN-Medtech, Department of Communication and Information Technologies, Pompeu Fabra University, Barcelona, Spain.ORCID 0009-0001-0638-6456
A GaldranPhysense, BCN-Medtech, Department of Communication and Information Technologies, Pompeu Fabra University, Barcelona, Spain.ORCID 0000-0002-5992-1520
M DelucchiInstitute of Computational Life Sciences, Zurich University of Applied Sciences, Waedenswil, Switzerland.ORCID 0000-0002-9327-1496
O CamaraPhysense, BCN-Medtech, Department of Communication and Information Technologies, Pompeu Fabra University, Barcelona, Spain.ORCID 0000-0002-5125-6132
J LiuLaboratory of Brain Atlas and Brain-Inspired Intelligence, Institute of Automation, Chinese Academy of Sciences, Beijing, China.ORCID 0009-0005-0515-9496
H HuangLaboratory of Brain Atlas and Brain-Inspired Intelligence, Institute of Automation, Chinese Academy of Sciences, Beijing, China.ORCID 0000-0001-6058-8115
Y CuiLaboratory of Brain Atlas and Brain-Inspired Intelligence, Institute of Automation, Chinese Academy of Sciences, Beijing, China.ORCID 0000-0002-5001-4940
Z LinSchool of Computer and Information Engineering, Xiamen University of Technology, Xiamen, China.ORCID 0009-0008-1601-4729
Y LiuSchool of Automation and Intelligent Sensing, Shanghai Jiao Tong University, Shanghai, China.ORCID 0009-0004-2624-9223
S ZhuSchool of Computer and Information Engineering, Xiamen University of Technology, Xiamen, China.ORCID 0000-0001-8321-1169
T R PatelCanon Stroke and Vascular Research Center, University at Buffalo, Buffalo, NY, USA.ORCID 0000-0002-4074-6822
A H SiddiquiCanon Stroke and Vascular Research Center, University at Buffalo, Buffalo, NY, USA.ORCID 0000-0002-9519-0059
V M TutinoCanon Stroke and Vascular Research Center, University at Buffalo, Buffalo, NY, USA.ORCID 0000-0002-1331-2551
M OrouskhaniDepartment of Radiology, University of Washington, Seattle, USA.ORCID 0000-0003-3341-3904
S HirschInstitute of Computational Life Sciences, Zurich University of Applied Sciences, Waedenswil, Switzerland.ORCID 0000-0002-5678-4110
S WegenerDepartment of Neurology, University Hospital of Zurich, Zurich, Switzerland.ORCID 0000-0003-4369-7023
B MenzeDepartment of Quantitative Biomedicine, University of Zurich, Zurich, Switzerland.ORCID 0000-0003-4136-5690
Funding
Investigation of the quantitative intracranial aneurysm wall enhancement and geometric features associated with aneurysm volume growthR01HL162743 · NHLBI · UNIVERSITY OF WASHINGTON · PI Chengcheng Zhu · 2022 to 2026
$2.4M
Characterization of intracranial vessel wall morphology and inflammation using 3D high resolution MRIR00HL136883 · NHLBI · UNIVERSITY OF WASHINGTON · PI ZHU, CHENGCHENG · 2020 to 2022
backgroundThe circle of Willis (CoW) is an important network of arteries connecting major circulations of the brain. Its vascular architecture is believed to influence the risk, severity, and outcome of serious neurovascular diseases. However, characterizing the highly variable CoW anatomy remains a manual and time-consuming expert task. The CoW is commonly imaged by two noninvasive angiographic imaging modalities - magnetic resonance angiography (MRA) and computed tomography angiography (CTA) - yet few datasets with annotated CoW anatomy exist, and there have been no established benchmarks for comparing CoW segmentation algorithms.
methodsWe organized the Topology-Aware Anatomical Segmentation of the Circle of Willis for Computed Tomography Angiography and Magnetic Resonance Angiography (TopCoW) benchmark challenge alongside the release of an annotated CoW dataset with 125 paired MRA and CTA scans from the same patients. Voxel-level annotations for 13 vessel components were created using virtual reality technology and verified by clinical experts. Participants submitted algorithms for CoW segmentation and variant classification, which we evaluated on internal and external test sets comprising 226 scans from over five centers. The benchmark includes voxel-level segmentation, CoW component detection, CoW variant classification, and two clinical application tasks.
resultsWe received submissions from over 250 participants across six continents. Top-performing teams achieved over 90% Dice similarity coefficient scores for CoW segmentation, over 80% F1 scores for detecting key vessel components, and over 70% balanced accuracy in CoW variant classification across nearly all test sets. The best algorithms also supported clinically relevant down-stream tasks by accurately classifying fetal-type posterior cerebral arteries and localizing aneurysms in relation to CoW anatomy. Notably, modality-agnostic models and topological optimization emerged as key factors in improving segmentation performance.
conclusionsThis benchmark demonstrated the utility of CoW segmentation algorithms for some downstream clinical applications with explainability. The annotated datasets and top-performing algorithms are published alongside this benchmark to foster methodological advances and clinical tool development. (Funded by the Digitalization Initiative of the Zurich Higher Education Institutions and the Helmut Horten Foundation.).
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.
The TopCoW Challenge - Topology-Aware Circle of Willis Segmentation for CT and MR Angiography. · full record | OpenQuestion