Evidence map›Paper›PMID 42629488›Full record

ArticleHypertension research : official journal of the Japanese Society of Hypertension2026

Evaluation of Alysis-001 cuffless blood pressure estimation algorithm against the European Society of Hypertension awake/asleep test criteria in hypertensive patients.

Kazuhiro Hongyo, Atsushi Hirayama, Kosuke Shimizu, Taisuke Ueno, Taku Fujimoto, Akitoshi Hara, Hiroshi Koriyama, Yoichi Takami, Yoshio Iwashima, Ryo Kawasaki and 1 more

Abstract read
PubMed Publisher
In one paragraph

Article in Hypertension research : official journal of the Japanese Society of Hypertension, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Kazuhiro Hongyo *Department of Geriatric and General Medicine, Graduate School of Medicine, The University of Osaka, Suita, Japan.
Atsushi Hirayama *Division of Public Health, Department of Social Medicine, Graduate School of Medicine, The University of Osaka, Suita, Japan.
Kosuke ShimizuArblet Inc., Tokyo, Japan.
Taisuke UenoDepartment of Geriatric and General Medicine, Graduate School of Medicine, The University of Osaka, Suita, Japan.
Taku FujimotoDepartment of Geriatric and General Medicine, Graduate School of Medicine, The University of Osaka, Suita, Japan.
Akitoshi HaraDepartment of Geriatric and General Medicine, Graduate School of Medicine, The University of Osaka, Suita, Japan.
Hiroshi KoriyamaDepartment of Geriatric and General Medicine, Graduate School of Medicine, The University of Osaka, Suita, Japan.
Yoichi TakamiDepartment of Geriatric and General Medicine, Graduate School of Medicine, The University of Osaka, Suita, Japan.
Yoshio IwashimaDepartment of Geriatric and General Medicine, Graduate School of Medicine, The University of Osaka, Suita, Japan.
Ryo KawasakiDivision of Public Health, Department of Social Medicine, Graduate School of Medicine, The University of Osaka, Suita, Japan.
Koichi YamamotoDepartment of Geriatric and General Medicine, Graduate School of Medicine, The University of Osaka, Suita, Japan. kyamamoto@geriat.med.osaka-u.ac.jp.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Accurate ambulatory blood pressure monitoring (ABPM) is essential for cardiovascular risk assessment and hypertension management, but conventional cuff-based ABPM causes discomfort and sleep disturbance, potentially affecting measurement reliability. The European Society of Hypertension (ESH) established evaluation criteria for cuffless blood pressure devices, with the awake/asleep test as the primary evaluation test for automated wearable devices. This study evaluated whether Alysis-001, a software-based cuffless blood pressure estimation algorithm using sensor data from a wrist-worn device, meets ESH awake/asleep test criteria in hypertensive patients under two data extraction strategies: (1) arm-stabilized periods only ( ≥ 10 s static); (2) including low-intensity activity (high-intensity excluded). We prospectively enrolled 92 hypertensive outpatients receiving antihypertensive treatment who simultaneously wore Alysis Wear and underwent conventional 24-h ABPM; 78 completed the study. Under both strategies, Alysis-001 demonstrated excellent agreement with reference ABPM across all measurement periods, with intraclass correlation coefficients exceeding 0.70 for systolic and diastolic blood pressure. Alysis-001 successfully met all ESH awake/asleep test criteria under both strategies: mean difference between awake-asleep blood pressure changes ≤5 mmHg, standard deviation ≤8 mmHg, and correlation coefficients ≥0.70 for both systolic and diastolic blood pressure. Alysis-001 also demonstrated high sensitivity, specificity, and accuracy in identifying non-dippers under both strategies. To our knowledge, this represents the first evaluation of a Device Type 3 cuffless blood pressure algorithm (automated, wearable, demographic-calibrated, not at heart level) meeting ESH awake/asleep test criteria, suggesting Alysis-001's potential as a clinically viable alternative for ambulatory blood pressure monitoring in hypertensive patients.

Indexed as

Ambulatory blood pressure monitoringCuffless blood pressure algorithmDigital hypertensionImplemental hypertension

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.