Evidence map›Paper›PMID 42623598›Full record

ArticleInternational braz j urol : official journal of the Brazilian Society of Urology

Precise Robotic Y-V Plasty for Vesico-Urethral Anastomotic Stenosis: Avoiding Urinary Incontinence.

Lin Wang, Fuhao Ji, Chao Yang, Chen Zhu, Yinglong Sa, Yidong Liu, Xiangguo Lv

Abstract read
In one paragraph

Article in International braz j urol : official journal of the Brazilian Society of Urology. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Lin WangDepartment of Urology, Renji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China.
Fuhao JiDepartment of Urology, Renji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China.
Chao YangDepartment of Urology, The Second Hospital of Anhui Medical University, Hefei, China.
Chen ZhuDepartment of Urology, Jiangsu Province Hospital of Chinese Medicine, Nanjing, China, Nanjing, China.
Yinglong SaDepartment of Urology, Shanghai Jiaotong University Affiliated Sixth People's Hospital, Shanghai, China.
Yidong LiuDepartment of Urology, Renji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China.
Xiangguo LvDepartment of Urology, Renji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveThe treatment of vesico-urethral anastomotic stenosis (VUAS) is difficult because of the high risk of urinary incontinence. Cystoscopy-guided robotic Y-V plasty is hypothesized to reduce the incidence of urinary incontinence compared to traditional Y-V plasty. The purpose of this study was to evaluate the efficacy of cystoscopy-guided robotic Y-V plasty. MATERIALS AND

methodsAll patients diagnosed with VUAS following radical prostatectomy between January 2019 and December 2024 were retrospectively reviewed. Patients with damaged external urethral sphincter or stenosis involving the external sphincter were excluded. Cystoscopy-guided robotic Y-V plasty was performed at least three months after the last failed intervention. After catheter removal, patients were scheduled for re-examination at one, six, twelve and twenty-four months. Uroflowmetry was routinely performed and cystoscopy was performed at six months after surgery. Postoperative changes in patients' erectile function, lower urinary tract symptoms, and urinary continence were followed up using Five-item International Index of Erectile Function (IIEF-5), International Prostate Symptom Score (IPSS), and urinary continence grading.

resultsTwenty-eight patients were enrolled. All patients were followed up for 6-59 (median 30) months after surgery. The final success rate was 96.4% (27/28). Normal continence was achieved in 25 patients (92.6%). Social continence occurred in 2 (7.4%). No patients experienced clinical incontinence. The patients' postoperative IPSS scores achieved significant improvement compared with preoperative.

conclusionThe surgical strategy cystoscopy-guided robotic Y-V plasty is more precise, direct and efficient in protecting the external urethral sphincter. It ensures a high success rate and simultaneously reduces the occurrence of urinary incontinence.

Indexed as

Robotic Surgical ProceduresUrethral StrictureUrinary BladderUrinary IncontinenceAgedAnastomosis, SurgicalCystoscopyHumansMaleMiddle AgedPostoperative ComplicationsProstatectomyRetrospective StudiesTreatment OutcomeUrethraProstatectomyRobotic Surgical ProceduresUrinary Incontinence

Identifiers

PMID42623598
PMCPMC13682756

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.