Evidence map›Paper›PMID 42622941›Full record

ArticleInternational journal of computer assisted radiology and surgery2026

A mixed reality hand fracture simulator for virtual K-wire fixation.

Jimmy Qiu, Trinette Wright, Stephanie Williams, Daniel Lin, Clare McElcheran, Stefan Hofer, Blake Murphy, Joseph Catapano

Abstract read
PubMed Publisher
In one paragraph

Article in International journal of computer assisted radiology and surgery, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Jimmy QiuTechna, University Health Network, 190 Elizabeth Street, Toronto, ON, M5G 2C4, Canada. jimmy.qiu2@uhn.ca.ORCID http://orcid.org/0000-0002-3686-3081
Trinette WrightTechna, University Health Network, 190 Elizabeth Street, Toronto, ON, M5G 2C4, Canada.ORCID http://orcid.org/0000-0002-3671-5839
Stephanie WilliamsTechna, University Health Network, 190 Elizabeth Street, Toronto, ON, M5G 2C4, Canada.ORCID http://orcid.org/0000-0003-2799-7624
Daniel LinTechna, University Health Network, 190 Elizabeth Street, Toronto, ON, M5G 2C4, Canada.ORCID http://orcid.org/0009-0007-2988-6051
Clare McElcheranTechna, University Health Network, 190 Elizabeth Street, Toronto, ON, M5G 2C4, Canada.ORCID http://orcid.org/0009-0002-1098-5141
Stefan HoferDivision of Plastic, Reconstructive and Aesthetic Surgery, University of Toronto, Toronto, ON, Canada.ORCID http://orcid.org/0000-0002-9653-2946
Blake MurphyDivision of Plastic, Reconstructive and Aesthetic Surgery, University of Toronto, Toronto, ON, Canada.
Joseph CatapanoDivision of Plastic, Reconstructive and Aesthetic Surgery, University of Toronto, Toronto, ON, Canada.ORCID http://orcid.org/0000-0001-6699-3146

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeProper management of hand fractures requires accurate reduction of bone fragments and stabilization with Kirschner wire (K-wire) fixation. Limited case exposure in residency and a shortage of feedback-rich skills assessment constrain deliberate practice. This work describes a mixed reality hand fracture simulator that integrates a realistic physical model with instrument tracking, real-time virtual image guidance, and quantitative performance feedback for training percutaneous K-wire fixation.

methodsWe developed a benchtop mixed reality (MR) simulator integrating an electromagnetic (EM) tracker, a three-dimensional (3D)-printed hand model with fracture patterns, and a microcontroller-enabled K-wire driver. To ensure high physical-to-virtual geometric correspondence, the 3D-printed components were optically scanned to serve as virtual representations. A custom application provides real-time 3D visualization, guidance, and simulated virtual X-rays. To evaluate system accuracy, five users performed repeated paired-point rigid registrations. Accuracy was assessed by calculating fiducial registration error (FRE) and target registration error (TRE) across 25 attempts using a pre-calibrated stylus and the tracked K-wire driver. Image guidance capabilities were evaluated by measuring positional and angular alignment errors of the tracked K-wire driver against predefined ideal trajectories.

resultsThe overall mean FRE was 0.69 ± 0.11 mm for the hand model (11 fiducials) and 0.60 ± 0.09 mm for the K-wire driver (8 fiducials). Target localization to six ground-truth targets yielded a mean TRE of 0.69 ± 0.10 mm with the stylus and 0.82 ± 0.16 mm with the driver. Trajectory alignment demonstrated maximum positional variance during parallel approaches to the bone (K-wire 1), highlighting specific procedural challenges.

conclusionsThe MR hand fracture simulator platform enables repeated practice of fracture reduction and K-wire placement with interactive guidance, simulated X-rays, and objective metrics. The system is able to achieve millimeter-scale alignment suitable for procedural training. Future work will evaluate learning outcomes and skill transfer in surgical trainees.

Indexed as

3D printingMixed realityPlastic surgerySurgical navigationSurgical simulation

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.