Evidence map›Paper›PMID 42622923›Full record

Trial reportHernia : the journal of hernias and abdominal wall surgery2026

A randomized controlled trial of a plastic-sheath technique to facilitate self-gripping mesh placement in laparoscopic inguinal hernia repair.

Jakrapan Jirasiritham, Chairat Supsamutchai, Napaphat Poprom, Thanida Janbavonkij, Pongsasit Singhatat, Tharin Thampongsa, Jarinya Wilasrusmee, Theejutha Meakleartmongkol, Settanan Plangsiri, Panupol Thepyasuwan and 1 more

Erratum issued Registry-linked trialAbstract readRandomized Controlled Trial
In one paragraph

Trial report in Hernia : the journal of hernias and abdominal wall surgery, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. It is linked to trial NCT04394338 (The Plastic Covering Method for Self-gripping Mesh Placement in Laparoscopic Inguinal Hernia Repair), which is not on this map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT04394338 nacompletednot on this map

The Plastic Covering Method for Self-gripping Mesh Placement in Laparoscopic Inguinal Hernia Repair

TypeinterventionalSponsorMahidol UniversityRan2020 to 2021Enrolled60ConditionsLaparoscopic Inguinal Hernia RepairArmsself-gripping mesh placement with plastic sheath in laparoscopic inguinal hernia
3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

11 authors.

Jakrapan JirasirithamDepartment of surgery, Faculty of Medicine, Ramathibodi Hospital, Mahidol University, Rama VI Road, Bangkok, Thailand.
Chairat SupsamutchaiDepartment of surgery, Faculty of Medicine, Ramathibodi Hospital, Mahidol University, Rama VI Road, Bangkok, Thailand.
Napaphat PopromDepartment of surgery, Faculty of Medicine, Ramathibodi Hospital, Mahidol University, Rama VI Road, Bangkok, Thailand.
Thanida JanbavonkijDepartment of surgery, Faculty of Medicine, Ramathibodi Hospital, Mahidol University, Rama VI Road, Bangkok, Thailand.
Pongsasit SinghatatDepartment of surgery, Faculty of Medicine, Ramathibodi Hospital, Mahidol University, Rama VI Road, Bangkok, Thailand.
Tharin ThampongsaDepartment of surgery, Faculty of Medicine, Ramathibodi Hospital, Mahidol University, Rama VI Road, Bangkok, Thailand.
Jarinya WilasrusmeeCollege of Medicine, Rangsit University, Pathum Thani, Thailand.
Theejutha MeakleartmongkolFaculty of Medicine Ramathibodi Hospital, Mahidol University, Bangkok, Thailand.
Settanan PlangsiriFaculty of Medicine Ramathibodi Hospital, Mahidol University, Bangkok, Thailand.
Panupol ThepyasuwanFaculty of Medicine Ramathibodi Hospital, Mahidol University, Bangkok, Thailand.
Chumpon WilasrusmeeDepartment of surgery, Faculty of Medicine, Ramathibodi Hospital, Mahidol University, Rama VI Road, Bangkok, Thailand. chumpon.wil@mahidol.ac.th.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundSelf-gripping mesh reduces recurrence and postoperative pain but is difficult to deploy due to its adhesive properties.

methodsWe developed a plastic-sheath covering technique to facilitate mesh placement. In Phase I, prototypes were evaluated for placement time and surgeon satisfaction. In Phase II, a randomized controlled trial (NCT04394338) compared the optimized sheath with conventional placement in laparoscopic inguinal hernia repair.

resultsPrototype 4 achieved the shortest placement time in Phase I. In Phase II (n = 26), the plastic-sheath method significantly reduced mesh placement time (4.56 ± 1.80 vs. 7.40 ± 1.52 min; P = 0.005) and improved surgeon satisfaction (8.00 vs. 6.31; P = 0.003). Postoperative pain, hospital stay, and complication rates were comparable between groups.

conclusionsThe plastic-sheath method simplifies self-gripping mesh deployment, reduces operative time, and improves surgeon satisfaction without increasing complications.

Indexed as

Hernia, InguinalHerniorrhaphyLaparoscopySurgical MeshAgedFemaleHumansLength of StayMaleMiddle AgedOperative TimePostoperative PainInguinal hernia repairLaparoscopic hernia repairSelf-gripping meshSurgical innovationTotal extraperitoneal (TEP) repairs

Identifiers

PMID42622923
PMCPMC13493447

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.