Evidence map›Paper›PMID 42622820›Full record

ArticlePediatric radiology2026

Radiographic imaging in pediatric suspected foreign body ingestion: potential for dose reduction through collimation and exposure strategies.

Max-Johann Sturm, Clemens Benoit, Jan-Peter Grunz, Stefan Weick, Franziska Müller-Reichart, Anke Dick, Oliver Andres, Thorsten Alexander Bley, Henner Huflage

Abstract read
PubMed Publisher
In one paragraph

Article in Pediatric radiology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Max-Johann SturmDepartment of Diagnostic and Interventional Radiology, University Hospital Würzburg, Oberdürrbacher Str. 6, Wurzburg, D-97080, Germany. Sturm_M@ukw.de.
Clemens BenoitDepartment of Diagnostic and Interventional Radiology, University Hospital Würzburg, Oberdürrbacher Str. 6, Wurzburg, D-97080, Germany.
Jan-Peter GrunzDepartment of Diagnostic and Interventional Radiology, University Hospital Würzburg, Oberdürrbacher Str. 6, Wurzburg, D-97080, Germany.
Stefan WeickDepartment of Radiation Oncology, University Hospital Würzburg, Wurzburg, Germany.
Franziska Müller-ReichartDepartment of Diagnostic and Interventional Radiology, University Hospital Würzburg, Oberdürrbacher Str. 6, Wurzburg, D-97080, Germany.
Anke DickDepartment of Pediatrics, University Hospital Würzburg, Wurzburg, Germany.
Oliver AndresDepartment of Pediatrics, University Hospital Würzburg, Wurzburg, Germany.
Thorsten Alexander BleyDepartment of Diagnostic and Interventional Radiology, University Hospital Würzburg, Oberdürrbacher Str. 6, Wurzburg, D-97080, Germany.
Henner HuflageDepartment of Diagnostic and Interventional Radiology, University Hospital Würzburg, Oberdürrbacher Str. 6, Wurzburg, D-97080, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundForeign body ingestion constitutes a common emergency in children. Radiography is essential for confirming presence, type, and location of ingested objects. International guidelines recommend broad anatomical coverage from the neck to the pelvis; however, the impact of radiographic exposure parameters and collimation on radiation dose remains underexplored.

objectiveTo evaluate the effects of different scan protocols on radiation dose in pediatric foreign body ingestion. MATERIALS AND

methodsTwo-hundred-twenty-one radiographs from 183 pediatric patients (median age 2.8 years [interquartile range 1.5-5.5 years]; 112 males, 71 females) performed between September 2019 and April 2025 were retrospectively analyzed. Radiographs were categorized as neck-upper abdomen, extended collimation including pelvis, or abdomen only. Notably, the first two protocols used chest radiograph exposure parameters. Data included patient demographics, foreign body type and location, radiographic protocol, dose-area product, and estimated effective dose.

resultsA foreign body was detected in 55.7% of radiographs, most of them in the stomach (59.4%). Coins were most common (31.7%), followed by button batteries (13.8%) and magnets (12.2%). Dose-area products were comparable between standard neck-to-upper-abdomen and extended neck-to-pelvis collimation but were markedly higher for abdomen-only imaging (P<0.001). Effective dose increased with extended collimation (P<0.05) and was highest for abdomen-only radiographs (0.053 mSv [0.034-0.086 mSv], P<0.001). No differences were observed in patient age or repeat imaging rates.

conclusionIn suspected pediatric foreign body ingestion, collimation and exposure parameters substantially influence radiation dose. Low-dose chest parameters combined with restrictive collimation minimize radiation exposure, whereas abdominal radiographs carry higher dose, attributable predominantly to the abdominal exposure parameters employed.

Indexed as

ChildForeign bodiesGastrointestinal tractMagnetsRadiation protectionRadiography

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.